Aprilaire 1700 Not in direct sunlight, Verify that the Outdoor Temperature Sensor

Page 15

TROUBLESHOOTING GUIDE (CONTINUED)

SYMPTOM

 

TROUBLESHOOTING PROCEDURE / POSSIBLE REASON

 

 

 

The ventilation damper does not open when the HVAC fan is active.

The damper will not open if the cycle time within the current period has already been met. For instance if the cycle time is set to 5 minutes and the control has already ventilated for 5 minutes in that interval, the damper will remain closed.

If using the Outdoor Temperature Sensor, check that it is installed in the Outdoor Air Intake a maximum of 3 feet from the outside, or on the North, East or West side of the house.

(Not in direct sunlight.)

If the outdoor temperature is below 0°F or above 100°F, the damper will remain closed.

Verify that the Outdoor Temperature Sensor

is reporting an accurate resistance. Remove the Outdoor Temperature Sensor leads from ODT Sensor terminals and check the resistance. Compare the reading with the resistance shown in Table 2.

TABLE 2

Outdoor

 

Temperature

Resistance

-30˚F

229,500 OHMS

-20˚F

162,500 OHMS

-10˚F

116,500 OHMS

0˚F

84,500 OHMS

10˚F

62,000 OHMS

20˚F

46,000 OHMS

30˚F

34,500 OHMS

40˚F

26,000 OHMS

50˚F

20,000 OHMS

60˚F

15,500 OHMS

70˚F

12,000 OHMS

80˚F

9,500 OHMS

90˚F

7,500 OHMS

100˚F

6,000 OHMS

The fan turns on unexpectedly.

The control will turn on the fan as needed to meet the air cycling requirements determined by the cycle time and cycle period settings.

The dehumidifier does not run.

Follow all of the system checkout procedures.

Check that the power switch on the dehumidifier is on.

Check that the circuit breaker is not tripped. The dehumidifier requires a minimum of 8 amps. The dehumidifier should be placed on its own dedicated 15 amp circuit.

The compressor never runs.

• If a float switch is not installed, confirm that the jumper is installed at the

 

float switch terminals on the control board.

 

• If a float switch is installed, confirm that the float switch is not open.

 

 

15

Image 15
Contents Table of Contents Installer Please NoteLocation Notes Safety InstructionsSpecifications OverviewOrientation of trap prior to DuctingDrain Line HangingWhole House Installation and Operation Dehumidifier Control Thermostat Hvac Equipment See page 12 for float switch wiring instructionsNone Duct Work Localized Installation and OperationWiring Cooling Coil AIR Cleaner Optional Model Hvac FAN OFF If equipped should open. do not leave the Cycle Time in Test Ventilation / FAN Cycling SettingsHouse Size Square feetBased on Ashrae 62.2 ventilation requirement Determines when the dampers are powered open or closed Float SwitchDIP Switch Definitions Default is Hvac FAN-OFFSystem Checkout Troubleshooting Guide Fan turns on unexpectedly Verify that the Outdoor Temperature SensorFloat switch terminals on the control board Not in direct sunlightDehumidifier Sequence of Operation Damper Sequence of OperationVentilation or FAN Cycling Sequence of Operation
Related manuals
Manual 4 pages 23.44 Kb

1700 specifications

The Aprilaire 1700 is a high-performance dehumidifier designed to effectively control humidity levels in residential and commercial spaces. This unit is particularly suitable for larger areas, with the capability to remove up to 70 pints of moisture per day, making it an ideal choice for basements, crawl spaces, and other large rooms prone to excess humidity.

One of the standout features of the Aprilaire 1700 is its durable construction. Built with robust materials, this dehumidifier is designed to withstand the rigors of continuous operation, ensuring longevity and reliable performance over time. Its compact design allows for easy installation, even in tight spaces, further enhancing its versatility.

The Aprilaire 1700 utilizes advanced dehumidification technology, featuring a 2-stage filtration system that not only removes moisture but also captures airborne allergens like dust and pollen. This makes the air in the home healthier and more comfortable for occupants, especially those with allergies or respiratory issues.

Another key characteristic of the Aprilaire 1700 is its built-in hygrometer, which allows for precise monitoring of humidity levels. The unit automatically adjusts its operation based on real-time humidity readings, ensuring optimal performance and energy efficiency. This smart technology helps in maintaining consistent humidity levels, preventing problems associated with excess moisture, such as mold growth and structural damage.

The unit can be integrated seamlessly with existing HVAC systems, allowing it to work in conjunction with your home’s heating and cooling systems for enhanced climate control. This integration also ensures quieter operation compared to portable dehumidifiers, making the Aprilaire 1700 an unobtrusive option for whole-home humidity management.

User-friendly controls on the unit allow for easy adjustments, enabling homeowners to set their desired humidity levels with ease. Additionally, the Aprilaire 1700 is designed for minimal maintenance, featuring a washable filter that can be cleaned and reused, contributing to cost savings over time.

In conclusion, the Aprilaire 1700 is a powerful and efficient solution for managing indoor humidity levels. With its robust construction, advanced technologies, and user-friendly features, it offers both comfort and peace of mind for homeowners looking to protect their living spaces from the negative effects of excess moisture. By investing in an Aprilaire 1700, users can enjoy a healthier indoor environment year-round.