Aprilaire 1700 installation instructions Model Hvac FAN OFF

Page 9

WHOLE HOUSE / LOCALIZED CONVERTIBLE INSTALLATION AND OPERATION (CONTINUED)

FIGURE 10 – WIRING

DEHUMIDIFIER SYSTEM DAMPERS

THERMOSTAT

R

C

G

W

Y

24VAC

(40 VA min)

TRANSFORMER

HVAC EQUIPMENT

R

C

WIRE NUT

G

W

Y

DEHUMIDIFIER

CONTROL

DAMPERS

VENT DEH

 

Rf

HVAC

Cf Gs

EQUIP.

Gh W

 

Y

See page 10 for ventilation control wiring instructions. See page 10 for fan cycling wiring instructions.

See page 12 for float switch wiring instructions.

FLOAT ODT A B + -

SWITCH SENSOR REMOTE

90-966

FIGURE 11 – SETTINGS

 

SYSTEM SETUP

Standard

Fan Cycling

Ventilation

 

OFF

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

OFF

OFF

OFF

 

MODEL 70

1

 

 

 

 

ON

MODEL 70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HVAC FAN

2

 

 

 

 

 

HVAC FAN

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHL HOUSE

 

3

 

 

 

 

 

CONVERTIBLE

ON

ON

ON

VENT-AUTO

4

 

 

 

 

 

VENT-TIMED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CYCLE PERIOD

Standard

Fan Cycling

Ventilation

 

 

 

 

 

 

 

30 MIN.

 

 

 

 

1

 

 

 

 

ON

OFF

See pages 10-11

See pages 10-11

 

 

 

 

 

 

 

2

 

 

 

 

 

1 HOUR

ON

See pages 10-11

See pages 10-11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 4

 

 

 

 

 

2 HOUR

OFF

See pages 10-11

See pages 10-11

 

 

 

 

 

 

3 HOUR

 

 

 

 

 

 

 

 

OFF

See pages 10-11

See pages 10-11

 

 

30

 

 

 

 

 

 

 

 

 

0

MIN.

60

 

 

 

 

 

 

 

 

 

 

 

 

MIN

 

 

 

 

 

MIN.

Standard

Fan Cycling

Ventilation

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

TEST

OFF

See pages 10-11

See pages 10-11

CYCLE TIME

90-965

9

Image 9
Contents Table of Contents Installer Please NoteSpecifications Safety InstructionsOverview Location NotesDrain Line DuctingHanging Orientation of trap prior toWhole House Installation and Operation Dehumidifier Control Thermostat Hvac Equipment See page 12 for float switch wiring instructionsNone Duct Work Localized Installation and OperationWiring Cooling Coil AIR Cleaner Optional Model Hvac FAN OFF If equipped should open. do not leave the Cycle Time in Test Ventilation / FAN Cycling SettingsHouse Size Square feetBased on Ashrae 62.2 ventilation requirement DIP Switch Definitions Float SwitchDefault is Hvac FAN-OFF Determines when the dampers are powered open or closedSystem Checkout Troubleshooting Guide Float switch terminals on the control board Verify that the Outdoor Temperature SensorNot in direct sunlight Fan turns on unexpectedlyDehumidifier Sequence of Operation Damper Sequence of OperationVentilation or FAN Cycling Sequence of Operation
Related manuals
Manual 4 pages 23.44 Kb

1700 specifications

The Aprilaire 1700 is a high-performance dehumidifier designed to effectively control humidity levels in residential and commercial spaces. This unit is particularly suitable for larger areas, with the capability to remove up to 70 pints of moisture per day, making it an ideal choice for basements, crawl spaces, and other large rooms prone to excess humidity.

One of the standout features of the Aprilaire 1700 is its durable construction. Built with robust materials, this dehumidifier is designed to withstand the rigors of continuous operation, ensuring longevity and reliable performance over time. Its compact design allows for easy installation, even in tight spaces, further enhancing its versatility.

The Aprilaire 1700 utilizes advanced dehumidification technology, featuring a 2-stage filtration system that not only removes moisture but also captures airborne allergens like dust and pollen. This makes the air in the home healthier and more comfortable for occupants, especially those with allergies or respiratory issues.

Another key characteristic of the Aprilaire 1700 is its built-in hygrometer, which allows for precise monitoring of humidity levels. The unit automatically adjusts its operation based on real-time humidity readings, ensuring optimal performance and energy efficiency. This smart technology helps in maintaining consistent humidity levels, preventing problems associated with excess moisture, such as mold growth and structural damage.

The unit can be integrated seamlessly with existing HVAC systems, allowing it to work in conjunction with your home’s heating and cooling systems for enhanced climate control. This integration also ensures quieter operation compared to portable dehumidifiers, making the Aprilaire 1700 an unobtrusive option for whole-home humidity management.

User-friendly controls on the unit allow for easy adjustments, enabling homeowners to set their desired humidity levels with ease. Additionally, the Aprilaire 1700 is designed for minimal maintenance, featuring a washable filter that can be cleaned and reused, contributing to cost savings over time.

In conclusion, the Aprilaire 1700 is a powerful and efficient solution for managing indoor humidity levels. With its robust construction, advanced technologies, and user-friendly features, it offers both comfort and peace of mind for homeowners looking to protect their living spaces from the negative effects of excess moisture. By investing in an Aprilaire 1700, users can enjoy a healthier indoor environment year-round.