INSTALLATION

Continued

Installation Items Needed

Before installing log set, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve*

test gauge connection*

adjustable (crescent) wrench or pliers

sediment trap

tee joint

pipe wrench

flexible gas line

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable al- ternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install exter- nal regulator with the vent pointing down as shown in Figure 2, page 3. Pointing the vent down protects it from freezing rain or sleet.

WARNING: Never connect

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Figure 3, page 4).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to appliance.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner orifice.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 3, page 4. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into log set controls. If sediment trap is not installed or is installed wrong, log set may not run properly.

natural gas appliance to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

External Regulator

Propane/LP Supply Tank

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to log set. If pipe is too small, undue loss of volume will occur.

Vent

Pointing

Down

Figure 2 - External Regulator on Propane/LP Supply Tank with Vent Pointing Down

901053-01J

www.desatech.com

3

Image 3
Contents Piezo Ignitor Electrode 901072-01 Propane/LP Brass Orifice Natural Gas Brass Orifice 901064-09 Jumper Wire 14580MV Valve 14512 With natural gas orifice 901073-01 Propane/LP Brass OrificeInstallation Connecting to GAS SupplyCheck GAS Type External Regulator Propane/LP Supply Tank Vent Pointing Down Installation Items NeededChecking GAS Connections Natural GasTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Natural Gas Installation GA9150A Remote Ready Valve Pilot Kit AssemblyBurner Inlet Fitting Propane/LP Gas ConversionScrew Thermopile Pilot Ignitor Piezo Cover Machine Cover Piezo IgnitorChanging Pilot Orifice Pilot Flow AdjustmentGas control valve conversion Mounting Screws Rubber Gasket Identification LabelLighting Instructions Remote Control Option HRC100For Your Safety Read Before Lighting OperatiOnTo Turn OFF GAS To Appliance Manual Lighting ProcedureOpTIONAL Remote OperationOn/Off Series Model HRC100 901053-01J Warranty Keep this WarrantyDesa HEATING, LLC Limited Warranties

GA9150A specifications

The Desa GA9150A is a notable gas heater that offers efficient heating solutions for various residential spaces. Designed for both functionality and aesthetics, the GA9150A embodies a perfect blend of modern technology and traditional design elements.

One of the main features of the Desa GA9150A is its powerful heating capacity. With an output of up to 25,000 BTUs, this gas heater is capable of warming up medium to large rooms quickly, ensuring comfort during the coldest winter months. Its versatile heating options include propane and natural gas, making it adaptable to various home setups and fuel availability.

The GA9150A is also equipped with a stylish, contemporary design that allows it to complement a wide range of home decors. Its sleek appearance is further enhanced by an easy-to-use control panel, providing users with the convenience of adjusting the heat settings according to their preferences.

Safety is a priority in the design of the Desa GA9150A. It includes an automatic shut-off feature that activates in case of low oxygen levels in the room, thereby ensuring peace of mind for users. Additionally, the heater has a built-in flame sensor that monitors the presence of a flame, providing an extra layer of security.

Another key characteristic of the GA9150A is its efficiency. This unit is designed to minimize energy consumption while maximizing output, making it a cost-effective option for homeowners. Its advanced technology allows for quick and effective heating, which can significantly reduce overall energy bills during the colder months.

The heater is also user-friendly, featuring a piezo ignition system that allows for easy start-up without the need for matches or lighters. The adjustable heat settings enable users to customize their heating experience, optimizing comfort and energy use.

In conclusion, the Desa GA9150A stands out in the market for its impressive heating capabilities, safety features, and energy efficiency. It is an excellent choice for anyone seeking a reliable and stylish gas heater that provides warmth and comfort throughout the home. With its blend of technology and thoughtful design, the GA9150A is a worthy investment for enhancing residential living spaces.