Caldera® has strived to bring you the ultimate in a gastop, while maintaining a high degree of usability. Please operate your unit sensibly and safely, while you enjoy the advantages of a technologically advanced control to enhance your cooking experience.

Detailed Operating Instructions

All models of the “Arrow” gastop family are equipped with an electronic Touch Control that senses the user’s touch through the ceramic glass panel.. The control can operate 4 or 5 gas burners depending on the model. Each burner has 21 levels of cooking (L, L 1/2, 1, 1 1/2,

2, 2 1/2 … H). Each burner has an “ON/OFF” selector key, an “Up” arrow key, a “Down” arrow key and a seven-segment LED display and a 1/2 level LED indicator. Additionally, the control has a “Lock” key that is used to generate a general “OFF” state for all burners while also locking the keyboard. The control is powered by a 120VAC, 60Hz properly grounded house outlet.

Initial Power Up

When power is first applied to the unit, or restored after a power outage, all LED’s will flash 8s in a sequential pattern for a maximum period of 30 seconds or until a key is touched. The flashing will then

stop and the LED in the will be lit indicating the gastop is unlocked and ready to use.

Unlocked mode

When the gastop is in Unlocked mode (Lock LED is on) all keys are potentially active but the “Up” and “Down” keys are temporarily inactive unless a burner is in programming mode. During Unlocked mode the “Lock” LED under the Caldera logo is “on” solid, indicating that the burners can now be programmed.

To Lock (Instant Off And Lock)

To instantly turn off all burners or to lock the controls the Lock key must be touched and held for 2 seconds, then the LED beneath the Lock key, will shut off, all burners will turn off and the control will beep once to indicate that the unit is in Lock mode. When Locked, the keys cannot be activated and do not emit a beep, if touched.

Automatic Locking And Deactivation

The gastop will also lock automatically if no burners have been used for ten minutes. This feature may be deactivated by touching the lock key and the front left ON/OFF Key for 3 seconds while all burners are off. Two beeps acknowledges deactivation, one beep indicates reactivation.

To Unlock

While in Lock mode, to activate the gastop, the Lock key must be touched and held for 2 seconds. After a 1.5 second touch, the control will beep once and the LED beneath the Lock key will turn “On“ indicating that the burners can be programmed.

Phone 800-725-7711

www.calderacorp.com Fax 800-962-3072

 

9

Image 9
Contents Touch Series Use and Care Manual Congratulations Page Important Safety Instructions Using Gas SafelyElectrical Requirements Safety Precautions Before Using Your GastopPage Page Operating instructions Safety FeaturesTo Unlock Automatic Locking And DeactivationUsing a Burner Warranty SS-69-10-0 Revised 06/23/06