PRODUCT AND SAFETY INFORMATION (CONT’D)

WARNING

User — Have this boiler serviced/inspected by a qualified service technician annually.

WARNING

Failure to adhere to the guidelines on this page can result in severe personal injury, death or substantial property damage.

WARNING

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas suppliers' instructions.

If you cannot reach your gas supplier, call the fire department.

BOILER OPERATION

Do not block flow of combustion or ventilation air to boiler.

Should overheating occur or gas supply fail to shut off, do not turn off or disconnect electrical supply to circulator. Instead, shut off the gas supply at a location external to the appliance.

Do not use this boiler if any part has been under water. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control that has been under water.

PRIMARY WATER

If you have an old system with cast iron radiators, thoroughly flush the system (without boiler connected) to remove sediment. The high-efficiency heat exchanger can be damaged by build-up or corrosion due to sediment.

Do not use petroleum-based cleaning or sealing compounds in boiler system. Gaskets and seals in the system may be damaged. This can result in substantial property damage.

Do not use “homemade cures” or “boiler patent medicines.” Substantial property damage, damage to boiler, and/or serious personal injury may result.

Continual fresh make-up water will reduce boiler life. Mineral buildup in heat exchanger reduces heat transfer, overheats the stainless steel heat exchanger, and causes failure. Addition of oxygen carried in by make-up water can cause internal corrosion in system components. Leaks in boiler or piping must be repaired at once to prevent make-up water.

FREEZE PROTECTION FLUIDS

CAUTION

NEVER use automotive or standard glycol antifreeze, even ethylene glycol made for hydronic systems. Use only inhibited propylene glycol solutions, which are specifically formulated for hydronic systems. Ethylene glycol is toxic and can attack gaskets and seals used in hydronic systems.

3

Image 4
Contents Page Table of Contents Product and Safety Information Special Attention BoxesProduct and Safety Information CONT’D What to do if YOU Smell GASGeneral Section II Maintenance ScheduleAdditional items if combustion or performance is poor Section II Maintenance Schedule CONT’D Section III Maintenance ProceduresCheck Combustion Air Inlets Check Pressure Relief ValveCheck Vent Piping Check Intake Air Vent PipingCheck primary and gas piping Operate Pressure Relief ValveFor Your Safety Read Before Operating Section IV Operations InstructionsReplacement Parts T50M/T80MBoiler Switch Condensate Outlet 80M/140M/199M Boiler 399M Boiler Heat Transfer Products, Inc LP-182 REV /18/06