Munchkin pmn user manual Section IV Operations Instructions, For Your Safety Read Before Operating

Page 9

GAS-FIRED BOILER

User Manual

SECTION IV – OPERATIONS INSTRUCTIONS

.FOR YOUR SAFETY READ BEFORE OPERATING.

WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electric switch; do not use any phone in your building

Immediately call your gas supplier from a neighbor’s phone. Follow the gas

suppliers’ instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to turn the gas control knob. Never use tools. If the handle will not turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

.OPERATING INSTRUCTIONS.

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

5.Remove front cover.

6.Turn gas shutoff valve to “off”. Handle will be vertical, do not force.

7.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP!

GAS

VALVE

GAS SHUT OFF VALVE

GAS VALVE SHUT OFF

MAIN GAS VALVE

Follow “B” in the safety information above on this label. If you don’t smell gas, go to next step.

8.Turn gas shutoff valve counterclockwise to “on”. Handle will be horizontal.

9.Install Front Cover.

10.Turn on all electric power to appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.

.TO TURN OFF GAS TO APPLIANCE.

1. Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance if service is to be performed.

3. Remove front cover.

4.Turn gas shutoff valve clockwise to “off”. Handle will be vertical. Do not force

5.Install Front Cover.

8

Image 9
Contents Page Table of Contents Special Attention Boxes Product and Safety InformationWhat to do if YOU Smell GAS Product and Safety Information CONT’DSection II Maintenance Schedule GeneralAdditional items if combustion or performance is poor Section III Maintenance Procedures Section II Maintenance Schedule CONT’DCheck Pressure Relief Valve Check Combustion Air InletsCheck Vent Piping Check Intake Air Vent PipingOperate Pressure Relief Valve Check primary and gas pipingSection IV Operations Instructions For Your Safety Read Before OperatingT50M/T80M Replacement PartsBoiler Switch Condensate Outlet 80M/140M/199M Boiler 399M Boiler Heat Transfer Products, Inc LP-182 REV /18/06