Beckett AFII manual HLX Firing Rate, HLX Air Dial Setting, FBX Firing Rate, FBX Air Dial Setting

Page 18

Section: Perform Regular Maintenance

HLX Firing Rate

Stop

AFII 85

AFII 100

AFII 150

Screw

 

 

 

0

0.40-0.65

0.5-0.65

0.75-1.00

 

 

 

 

1

-

0.6-0.75

0.85-1.10

 

 

 

 

2

-

0.65-0.80

0.95-1.15

 

 

 

 

3

0.60-0.75

0.65-0.90

0.95-1.20

 

 

 

 

4

-

0.75-0.95

1.10-1.25

 

 

 

 

5

0.70-0.85

0.85-1.00

1.15-1.35

 

 

 

 

6

-

0.95-1.10

1.15-1.40

 

 

 

 

7

-

-

1.25-1.50

 

 

 

 

8

-

-

1.30-1.50

 

 

 

 

HLX Air Dial Setting

Firing Rate

AFII 85

AFII 100

AFII 150

@ 140 psig

 

 

 

0.40-0.65

3

-

-

 

 

 

 

0.60-0.75

4

3

-

 

 

 

 

0.70-0.85

5

4

-

 

 

 

 

0.75-1.00

-

5

2

 

 

 

 

0.95-1.20

-

-

3

 

 

 

 

1.15-1.35

-

-

4

 

 

 

 

1.25-1.50

-

-

5

 

 

 

 

FBX Firing Rate

Head

AFII 85

 

AFII 100

 

AFII 150

 

 

 

 

 

 

 

 

FB0

0.40-0.65

 

0.55-0.75

0.75-1.00

 

 

 

 

 

 

 

 

FB3

0.55-0.85

 

0.55-1.10

0.85-1.20

 

 

 

 

 

 

 

 

FB4

 

-

 

0.75-1.10

1.10-1.25

 

 

 

 

 

 

 

 

FB6

 

-

 

0.85-1.15

 

1.15-1.35

 

 

 

 

 

 

 

 

FBX Air Dial Setting

 

 

 

 

 

 

 

 

 

Firing Rate @

AFII 85

 

AFII 100

AFII 150

140 psig

 

 

 

 

 

 

0.40-0.65

3

 

 

-

 

-

 

 

 

 

 

 

 

0.60-0.75

4

 

 

3

 

-

 

 

 

 

 

 

 

0.70-0.85

5

 

 

4

 

-

 

 

 

 

 

 

 

0.75-1.00

-

 

 

5

 

2

 

 

 

 

 

 

 

0.95-1.20

-

 

 

-

 

3

 

 

 

 

 

 

 

1.15-1.35

-

 

 

-

 

4

 

 

 

 

 

 

 

1.25-1.50

-

 

 

-

 

5

 

 

 

 

 

 

 

 

18

Image 18
Contents Potential for Fire, Smoke and Asphyxiation Hazards To the Homeowner or Equipment OwnerPage Contents General Information Inspect/Prepare Installation Site Air Tube Combinations ATC & Dimensions Fire, Smoke & Asphyxiation HazardDirect/Sidewall Venting Application Outside Air ConnectionFuel Line Valves and Filter Prepare the BurnerDo Not Use Teflon Tape GeneralSpecial wiring required with covered burners Wire BurnerBurner installed at jobsite Mount Burner on ApplianceIncorrect Wiring Will Result in Improper Control Operation FeaturesWiring Explosion, Fire, Scald, Burn Hazard Burner ControlsValve-on delay Reset Button Operation Status LightsControl System Features Wire Burner Start Up Burner and Set CombustionHot Gas Puff-Back Heavy Smoke Hazard Annual Professional Service Required Section Perform Regular MaintenanceNozzle Installation Nozzle Flow Rate by SizeCheck/Adjust Electrodes Blower Wheel ReplacementCombinations HLX Firing Rate HLX Air Dial SettingFBX Air Dial Setting FBX Firing RateReplacement Parts Description Kit NoLimited Warranty Information