IDEAL INDUSTRIES C24 Introduction, Safety, Electricity Supply, Important Notes Boiler Controls

Page 2

back

Mini

Mini C24

G.C. appliance No. 47---

348---

18

Mini C28

G.C. appliance No. 47---

348---

19

Mini C32

G.C. appliance No. 47---

348---

25A

Mini S24

G.C. appliance No. 41---

392---

98

Mini S28

G.C. appliance No. 41---

392---

99

Destination countries: GB, IE

INTRODUCTION

Mini are wall mounted, room sealed, non condensing boilers featuring full sequence automatic spark ignition and fan assisted combustion.

Mini C24, Mini C28 and Mini C32 are low water content combination gas boilers.

Mini S24 and Mini S28 are low water content system gas boilers.

SAFETY

Current Gas Safety (Installation & Use)

Regulations or rules in force

In your own interest, and that of safety, it is the law that this boiler must be installed by CORGI registered installer or in IE a competent person, in accordance with the above regulations.

It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.

ELECTRICITY SUPPLY

The appliance must be efficiently earthed.

Supply 230 V 50 Hz. The fusing should be 3 A.

Connection must be made in a way that allows complete isolation of the electrical supply, such as a double pole switch, having a 3 mm (1/8”) contact separation in both poles, or a plug and socket serving only the boiler and system controls. The means of isolation must be accessible to the user after installation.

IMPORTANT NOTES

BOILER CONTROLS

Mini C24

Mini C28

Mini C32

A B C D EF G

Mini S24

Mini S28

AAppliance On lamp

BDomestic hot water temperature control

CMain switch and radiator temperature control

DBoiler reset button

ELock---out signal lamp

FProgrammer (optional)

GSystem pressure and temperature gauge

TO LIGHT THE BOILER

1Check that the valves located in the lower part of the boiler are open.

2Switch the the electricity supply on.

The appliance On lamp A will flash every 4 seconds (stand---by condition).

For combination models Mini C24, Mini C28 and Mini C32

3If the boiler is to be used for CH and DHW position the main switch as in the following illustration.

The appliance On lamp A will flash every 2 seconds (operating boiler).

AC

FThis appliance must not be operated without the casing correctly fitted and forming an adequate seal.

FIf the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes.

FUnder no circumstances should any of the sealed components on this appliance be used incorrectly or tampered with.

FIf it is known or suspected that a fault exist on the boiler then it MUST NOT BE USED until the fault has been corrected by a CORGI registered installer or in IE a competent person.

MINIMUM CLEARANCES

Clearances of 200 mm (7 7/8“) above and below, 25 mm (1“) at left, 50 mm (2“) at right and 450 mm (17 3/4“) at the front of the boiler case must be allowed for servicing.

After installation the following clearances are allowable during use, providing the encasing parts are removeable for servicing:

The bottom clearance can be reduced to 20mm (3/4”). The front clearance can be reduced to 50mm (2”).

For system models Mini S24 and Mini S28

4To operate the boiler position the main switch as in the following illustration.

The appliance On lamp A will flash every 2 seconds (operating boiler).

AC

All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in your Benchmark Log Book. You can check your installer by calling CORGI direct on 01563 72300

Caradon Ideal Limited is a member of the Benchmark initiative and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.

THE LOG BOOK SHOULD BE COMPLETED AFTER EACH SERVICE AND KEPT WITH THESE INSTRUCTIONS

Image 2
Contents Users guide Electricity Supply SafetyIntroduction Important Notes Boiler ControlsMaintenance Control of CH TemperatureCleaning FaultsIdeal Consumer Helpline Tel 01482
Related manuals
Manual 4 pages 7.56 Kb