Stop!! — Read before proceeding

AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual

Stop!! — Read before proceeding

Failure to adhere to the following guidelines can result in severe personal injury, death or substantial property damage.

When servicing boiler

To avoid electric shock, disconnect electrical supply before performing maintenance.

To avoid severe burns, allow boiler to cool before performing maintenance.

Boiler operation

Do not block flow of combustion or ventilation air to boiler.

Should overheating occur or gas supply fail to shut off, do not turn off or disconnect electrical supply to circulator. Instead, shut off the gas supply at a location external to the appliance.

Do not use this boiler if any part has been under water. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control that has been under water.

Boiler water

Do not use petroleum-based cleaning or sealing compounds in boiler system. Water seal deterioration will occur, causing leakage between sections. This can result in substantial property damage.

Do not use "homemade cures" or "boiler patent medicines". Serious damage to boiler, personnel and/or property may result.

Continual fresh makeup water will reduce boiler life. Mineral buildup in sections reduces heat transfer, overheats cast iron, and causes section failure. Addition of oxygen and other gases can cause internal corrosion. Leaks in boiler or piping must be repaired at once to prevent makeup water.

Do not add cold water to hot boiler. Thermal shock can cause sections to crack.

Glycol — potential fire hazard

All glycol is flammable when exposed to high temperatures. If glycol is allowed to accumulate in or around the boiler or any other potential ignition source, a fire can develop. In order to prevent potential severe personal injury, death or substantial property damage from fire and/or structural damage:

Never store glycol of any kind near the boiler or any potential ignition source.

Monitor and inspect the system and boiler regularly for leakage. Repair any leaks immediately to prevent possible accumulation of glycol.

Never use automotive antifreeze or ethylene glycol in the system. Using these glycols can lead to hazardous leakage of glycol in the boiler system.

Part number 550-141-893/0800

3

 

Image 3
Contents User’s Information Manual AHE SERIESDirect Vent Wall-Mounted Boilers Stop!! - Read before proceeding - Important safety information ContentsPlease read this page first Hazard definitionsBoiler water When servicing boilerStop!! - Read before proceeding Boiler operationService technician Boiler maintenanceBoiler service and maintenance Maintenance scheduleComponent information User maintenance proceduresBoiler must be serviced and maintained DailyCheck venting system User maintenance procedures continuedMonthly Check boiler pipingTest low water cutoff Clean vent termination and air intake screensPeriodically Main burner flamesOperate relief valve Shut down procedureEvery 6 months End of seasonOPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATINGOperating instructions Robertshaw 7200 gas valveHoneywell VR8205 and White-Rodgers 36E gas valves Operating instructions - Robertshaw 7200 gas valvePossible Corrections Common problems and solutionsSymptom Common CausesLimited Warranty for cast iron sections Weil-McLain Limited Warranty forCOMMERCIAL WARRANTY-Limited 10-Year Limited Warranty for Cast Iron Boilers