Kenmore 5EW1.75, 4EW.90, 3EW.75, 3E W.65, 5EW2.00, 5EWL.20, 4EW1.50 owner manual Introduction, TIEml

Page 3

INTRODUCTION

The Empire Water boiler is a natural draft oil fired hot water boiler comprised of cast iron sections. The Empire

Water boiler is available with 3, 4, or 5 cast iron sections. These sections are held together by cast iron push nipples.

The Empire Water boiler is capable of firing #2 fuel oil from 0.65 gph up to 2.00 gph. Boilers may be purchased with or without the following options: a Beckett AFG, Carlin EZ, or Rie[lo 40 oil burner, a Taco or Grundfos

circulator with isolation valves, a tankless coil for domestic hot water. All packaged boilers include a swing door, Honeywell aquastat, temperature and pressure gage, relief valve, drain valve, 2 Delevan oil nozzles for

multiple firing rates (only when purchasing a burner), flue brush, and an extra boiler tap for an expansion tank or air elimination.

36"

--*-- 2o I/2"

TIE_ml

GAUGIE

PRIESSUR_

r

i

UMIT

jCONTROL (W_lh=_t

Tanklos=

oll)

LIMIT

CONTROL

(_Bh

Tonkiel=

co==)

BURN

,7.l/a"

A

 

RIEU.O

 

 

T3

3/4"

 

 

BIECKETT

 

 

OR

 

 

CARUN

 

 

 

t I P-'f

'_WATIER

OPTIONAL

 

I I I--.-.I

OUTLET

TANKLESS

 

 

J

COIL

 

 

 

WATIER

HEATER

WITH 1/2" NPT

CONNECTIONS

RIEUIEF

VALVIE "_

OUTLET

1/4"

RETURN

NIPPLE

&

RIEDUCING TEE

FRONT VIEW

DRAIN

VALVE (Furnished)

RIGHT SIDE VIEW

WITH SWING DOOR

BACK VIEW

Image 3 Contents
Off-Fired Hot Water Boiler Kennmore Cast Iron Boilers TIEml IntroductionCapacities RatingsRules for Safe Installation and Opeiltion Locating the Boiler Installation Requirelments Inote Fresh AIR for CombustionDuct Size Twothrottlingvalves to System PipingSupply to System System Piping Arrangement Zoning with Zone ValvesSystem Piping Arrangement Zoning with Circulators System Piping Arrangement Alternate Near Boiler Piping Burner Firing Number Recommended Minimum Chimney Sizes Chimney and Chimney ConnectionsTypical Chimney Connection Thermostat Electrical ConnectionsSE/ARS Automatic Fill Valve not provided HOW a HOT Water System Operates Filling the BoilerBeckett OIL BURNER, NOZZLE, and AIR Settings Final Burner Adjustments GAP 32 4 mm 64 to 7/64 or 2 to 2.5 m 32 or 4 mm Checking and Adjusting Controls Maintenance OIL Boiler / Burner Cleaning Instructions OIL Burner Cleaning To do Electrical WiringSoP.LY Service Company Serviceman Address Telephone Operation SequenceSequence of Operation Boiler Less Tankless Coil Parts RepairPa # Balloon 5YMBOL KEY Description Repair PartsBeckett OIL Burner NOZZLE, and AIR Settings Oi/-Fired Hot Water Boiler