Lochinvar 151, 286 manual Call for Heat

Page 12

Outdoor Knight Boiler User’s Information Manual

4 SMART SYSTEM control module

Figure 5 Status Display Screen

A

(BOILER

STATUS)

C

(OPERATIONAL

INFORMATION)

D

(LEFT SELECT

KEY)

E

B

(CALL FOR

HEAT)

F

(RIGHT SELECT KEY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(NAVIGATION DIAL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status Display Screens

Section

 

 

Display

 

 

 

Description

 

STANDBY

 

 

 

The unit has not received a call for heat from a remote thermostat nor

 

 

 

 

has it received a call for heat from a DHW thermostat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START

 

 

 

The unit has begun a burn cycle and is checking all safety circuits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PREPURGE

 

 

 

The unit has initiated a prepurge period on a call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IGNITION

 

 

 

The unit has begun a spark period to ignite the main burner.

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

%

 

 

 

 

 

 

 

 

The unit has fired and is running at the displayed percentage.

(Boiler Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The call for heat has been satisfied and the unit runs the fan for an

Bar)

POSTPURGE

 

 

 

additional postpurge period to clear the combustion chamber and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

vent system of residual flue products.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTDOWN

 

 

 

The unit has been placed in the OFF position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The controlled temperature has exceeded its set point and its offset.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOCKED

 

 

 

The unit has detected a condition that has temporarily interrupted

 

 

 

 

the current call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Room Thermostat 1 has a call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Room Thermostat 2 has a call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Room Thermostat 3 has a call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Call for Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The tank thermostat or sensor has a call for heat.

Indicators)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates which room thermostat demand shows priority.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The unit is being controlled by a 0 - 10V BMS signal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The member unit is supplying heat while in Cascade Mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Image 12
Contents Outdoor Knight Boiler User’s Information Manual Models 151 Contents Boiler service and maintenance Please read before proceedingPrevent combustion air contamination Products to avoidAreas likely to have contaminants Maintenance schedule Service technician GeneralMaintenance schedule Fill condensate trap with waterCondensate Trap Condensate disposalCheck air vents Operating instructions Installer Smart System control moduleUser Temperature Units Night Setback OverrideSpace heating SH1, SH2, SH3 and tank set points Call for Heat Smart System control module Dial Function Outdoor Knight Boiler User’s Information Manual
Related manuals
Manual 76 pages 1.76 Kb

286, 151 specifications

Lochinvar 151,286 is a notable model in the realm of commercial water heating solutions, designed primarily for large-scale applications. This model incorporates advanced technologies and features that set it apart in terms of efficiency, usability, and reliability.

One of the hallmark features of Lochinvar 151,286 is its high-efficiency system that leverages condensing technology. This technology enables the unit to extract additional heat from exhaust gases, allowing it to operate at an impressive annual fuel utilization efficiency (AFUE) rating. This not only reduces energy consumption, but it also significantly lowers operational costs.

The Lochinvar 151,286 is equipped with a robust stainless steel heat exchanger, which provides both durability and enhanced thermal efficiency. This design withstands the rigors of high-demand environments, making it ideal for restaurants, schools, hospitals, or any facility requiring consistent hot water supply. Its compact footprint allows it to be installed in tight spaces without sacrificing performance.

Another standout characteristic is its intelligent control system. The built-in touchscreen interface offers users an intuitive way to manage settings, monitor performance, and troubleshoot issues. This smart technology aids in simplifying maintenance and improves overall system reliability. The unit also features advanced safety protocols, including multiple sensors that monitor operation and provide alerts in case of irregular performance.

In terms of capacity, the Lochinvar 151,286 can deliver an impressive output, accommodating varying demands with ease. Its innovative modulation capabilities allow the unit to adjust its heating output based on real-time hot water needs, ensuring unmatched comfort and efficiency.

Supporting the model’s performance are versatile connectivity options. Lochinvar 151,286 can integrate seamlessly with building management systems, allowing facility managers to monitor and control heating processes remotely. This level of connectivity not only enhances control but also supports energy-saving strategies across the facility.

In conclusion, Lochinvar 151,286 stands out as a premium choice for commercial water heating needs. With its high-efficiency ratings, durable construction, intelligent control system, impressive capacity, and versatile connectivity, it ensures that hot water is delivered reliably and efficiently, meeting the demands of modern businesses while reducing energy costs. This combination of technology and design makes it an essential component for any large-scale facility focused on performance and sustainability.