Lochinvar 151, 286 manual Dial Function

Page 14

Outdoor Knight Boiler User’s Information Manual

4 SMART SYSTEM control module

Status Display Screens (cont’d)

Section

 

 

Display

Description

 

MENU

Press and hold the LEFT SELECT key for 5 seconds to enter the Menu

 

Screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXIT

Press the LEFT SELECT key to exit the current screen or setting.

 

 

 

 

 

 

 

 

 

 

D

YES

Press the LEFT SELECT key to confirm that the boiler needs to

shutdown.

(LEFT SELECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the LEFT SELECT key to enter the screen that allows you to

key function)

LIMITS

adjust the limit settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

HOME

Press the LEFT SELECT key to return to the Status Screen and upload

 

parameter changes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SKIP

Press the LEFT SELECT key when in the Night Setback Screen to

 

access the Night Setback Skip Screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turning the NAVIGATION dial will select the next or previous Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressing the NAVIGATION dial will show the next fault, NSB (Night

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setback) trigger, or ramp delay setting.

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

Pressing the NAVIGATION dial will select the setting indicated by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the cursor.

(NAVIGATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dial Function)

 

 

 

 

 

 

 

 

Pressing the NAVIGATION dial will display the Set Points Screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turning the NAVIGATION dial will move the cursor up or down.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turning the NAVIGATION dial will increase or decrease the current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

setting.

 

 

 

 

 

 

 

 

 

 

 

SHDN

Press the RIGHT SELECT key to turn the boiler OFF.

 

 

 

 

 

 

 

 

 

 

 

ON

Press the RIGHT SELECT key to turn the boiler ON.

F

 

 

 

 

 

 

 

 

 

NO

Press the RIGHT SELECT key to cancel the shutdown operation.

(RIGHT SELECT

key function)

 

 

 

 

 

 

 

 

 

SAVE

Press the RIGHT SELECT key to save the current change.

 

 

 

 

 

 

 

 

 

 

 

 

HOME

Press the RIGHT SELECT key to return to the Status Screen and

 

upload parameter changes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

Image 14
Contents Outdoor Knight Boiler User’s Information Manual Models 151 Contents Boiler service and maintenance Please read before proceedingAreas likely to have contaminants Prevent combustion air contaminationProducts to avoid Maintenance schedule Service technician GeneralMaintenance schedule Fill condensate trap with waterCondensate Trap Condensate disposalCheck air vents Operating instructions User InstallerSmart System control module Space heating SH1, SH2, SH3 and tank set points Temperature UnitsNight Setback Override Call for Heat Smart System control module Dial Function Outdoor Knight Boiler User’s Information Manual
Related manuals
Manual 76 pages 1.76 Kb

286, 151 specifications

Lochinvar 151,286 is a notable model in the realm of commercial water heating solutions, designed primarily for large-scale applications. This model incorporates advanced technologies and features that set it apart in terms of efficiency, usability, and reliability.

One of the hallmark features of Lochinvar 151,286 is its high-efficiency system that leverages condensing technology. This technology enables the unit to extract additional heat from exhaust gases, allowing it to operate at an impressive annual fuel utilization efficiency (AFUE) rating. This not only reduces energy consumption, but it also significantly lowers operational costs.

The Lochinvar 151,286 is equipped with a robust stainless steel heat exchanger, which provides both durability and enhanced thermal efficiency. This design withstands the rigors of high-demand environments, making it ideal for restaurants, schools, hospitals, or any facility requiring consistent hot water supply. Its compact footprint allows it to be installed in tight spaces without sacrificing performance.

Another standout characteristic is its intelligent control system. The built-in touchscreen interface offers users an intuitive way to manage settings, monitor performance, and troubleshoot issues. This smart technology aids in simplifying maintenance and improves overall system reliability. The unit also features advanced safety protocols, including multiple sensors that monitor operation and provide alerts in case of irregular performance.

In terms of capacity, the Lochinvar 151,286 can deliver an impressive output, accommodating varying demands with ease. Its innovative modulation capabilities allow the unit to adjust its heating output based on real-time hot water needs, ensuring unmatched comfort and efficiency.

Supporting the model’s performance are versatile connectivity options. Lochinvar 151,286 can integrate seamlessly with building management systems, allowing facility managers to monitor and control heating processes remotely. This level of connectivity not only enhances control but also supports energy-saving strategies across the facility.

In conclusion, Lochinvar 151,286 stands out as a premium choice for commercial water heating needs. With its high-efficiency ratings, durable construction, intelligent control system, impressive capacity, and versatile connectivity, it ensures that hot water is delivered reliably and efficiently, meeting the demands of modern businesses while reducing energy costs. This combination of technology and design makes it an essential component for any large-scale facility focused on performance and sustainability.