Ariston 41-116-05 installation instructions Installation, Overall View, Reference Standards

Page 4

1.2OVERALL VIEW

LEGEND:

 

1.

Flue connector

2.

Air intake for twin pipe flue systems

3.

Fan

4.

Combustion chamber hood

5.

Main heat exchanger

6.

Safety thermostat

7.

Combustion chamber

8.Combustion chamber insulation panel

9. Detection electrode

10. Ignition electrodes

11. Burner

12. Regulation thermostat

13. Frost thermostat

14. Pump pressure switch

15. Safety valve (3 bar)

16. Automatic By-pass

17. Gas valve

18. Spark generator

19. Boiler drain valve

20. Circulation pump with automatic air release valve

21. Expansion vessel

22. Air pressure take-off point

23.Air pressure switch

24. Combustion analysis points

FIG. 1.0

2.INSTALLATION

2.1REFERENCE STANDARDS

The technical information and instructions provided herein below are intended for the installer so that the unit may be installed correctly and safely.

The installation and initial start up of the boiler must be by a CORGI Registered Installer in compliance with the installation standards currently in effect, as well as with any and all local health and safety standards i.e. CORGI .

This appliance must be installed by a competent installer in accordance with current Gas Safety (installation & use) Regulations.

The installation of this appliance must be in accordance with the relevant requirements of the current Gas Safety (installation & use) Regulations, the Local Building Regulations, the current I.E.E. Wiring Regulations, the byelaws of the local water authority, and in Scotland, in accordance with the Building Standards (Scotland) Regulation and Health and Safety document No. 635 “Electricity at work regulations 1989”.

Installation should also comply with the following British Standard Codes of Practice:

BS 7593:1992

Treatment of water in domestic hot water central

 

heating systems

BS 5546:1990

Installation of hot water supplies for domestic

 

purposes

BS 5440-1:1990

Flues

BS 5440-2:1989

Air supply

BS 5449:1990

Forced circulation hot water systems

BS 6789:1987

Installation of gas fired hot water boilers of rated

 

input not exceeding 60kW

BS 6891:1989

Installation of low pressure gas pipe up to 28mm

BS 7671:1992

IEE wiring regulations

BS 4814:1990

Specification for expansion vessels

BS 5482:1994

Installation of LPG

4

Image 4
Contents Installation Instructions Type C Boilers Table of Contents General Instructions Overall View InstallationReference Standards Overall Dimensions Siting the ApplianceClearances Mounting the Appliance Electrical ConnectionGAS Connection Water ConnectionsResidual Head of the Boiler Flue Connections Tower Flue Components80 mm Rffi Room Thermostat ConnectionElectrical Diagram On/Off SwitchGAS and Water Circuits 2 Port and 3 Port Valve Installations H.W. Storage CylinderModel Domestic HOT Water Priority KIT CommissioningInitial Preparation Control Panel Removing the Front PanelInitial START-UP Combustion Analysis Fume Discharge MonitoringBoiler Safety Systems Draining the System GAS Adjustments MaintenanceRffi Changing the Type of GASTechnical Information Number 41-116-05

41-116-05 specifications

The Ariston 41-116-05 is an innovative and efficient appliance designed to meet modern home heating and comfort needs. As part of Ariston's extensive portfolio, this model embodies the brand's commitment to quality and sustainability.

One of the main features of the Ariston 41-116-05 is its advanced energy efficiency rating. It incorporates cutting-edge technology to optimize energy consumption, helping homeowners reduce their utility bills while minimizing their environmental impact. This aligns with the growing demand for eco-friendly heating solutions in today's market.

The heater is equipped with a powerful heating element, capable of quickly generating warmth even in larger spaces. Its robust performance ensures that rooms reach the desired temperature rapidly, providing comfort during cold weather conditions. The unit is designed with multiple heat settings, allowing users to customize the warmth level according to their preferences and specific needs.

Moreover, the Ariston 41-116-05 features an intuitive digital control panel. This user-friendly interface makes it easy for individuals to adjust settings, monitor energy consumption, and set timers for automatic operation. Some models also offer Wi-Fi connectivity, enabling users to control their heating remotely via a smartphone app. This feature is particularly beneficial for those who want to maintain a comfortable environment in their homes while controlling energy use.

Safety is another cornerstone of the Ariston 41-116-05’s design. The appliance is equipped with multiple safety mechanisms, including overheat protection and a tip-over switch. These features ensure that the unit operates safely and securely, providing peace of mind for homeowners.

In summary, the Ariston 41-116-05 is a modern appliance that combines efficiency, performance, and safety. Its exceptional energy-saving capabilities, user-friendly controls, and robust heating power make it an ideal choice for anyone seeking reliable home heating solutions. With its range of features and commitment to sustainability, the Ariston 41-116-05 stands out as a valuable addition to contemporary households, enhancing comfort while being mindful of the environment.