Ariston 41-116-05 installation instructions GAS Connection, Water Connections

Page 6

FIG. 2.2

N

L

E

The boiler operates with alternating current, as indicated in the technical information table in section 7, where the maximum absorbed power is also indicated. Make sure that the connections for the neutral and live wires correspond to the indications in the diagram. The appliance electrical connections are situated on the reverse of the control panel under the inspection cover (see the servicing manual for further information)

 

 

IMPORTANT!

 

 

 

In the event that the power supply cord must be changed, replace it with one with the

 

 

same specifications. Make the connections to the terminal board located within the

 

 

control panel, as follows:

 

 

 

- The yellow-green wire should be connected to the terminal marked with the

 

 

symbol;

 

 

 

- The blue wire should be connected to the terminal marked “N”;

 

 

 

- The brown wire should be connected to the terminal marked “L”.

 

 

 

Note: The diagrams for the electrical system are indicated in section 2.12.

 

 

 

Warning, this appliance must be earthed.

 

 

 

External wiring to the appliance must be carried out by a competent person and be

 

 

in accordance with the current I.E.E. Regulations and applicable local regulations.

 

 

The microSYSTEM range of boilers are supplied for connection to a 230 V~

50 Hz

 

 

supply.

 

 

 

The supply must be fused at 3 A.

 

 

 

The method of connection to the electricity supply must facilitate complete electrical

 

 

isolation of the appliance, by the use of a fused double pole isolator having a contact

 

 

separation of at least 3 mm in all poles or alternatively, by means of a 3 A fused

 

 

three pin plug and unswitched shuttered socket outlet both complying with BS 1363.

 

 

The point of connection to the Electricity supply must be readily accessible and

 

 

adjacent to the appliance unless the appliance is installed in a bathroom when this

 

 

must be sited outside the bathroom (see section 2.2).

 

2.7

GAS CONNECTION

The local gas region contractor connects the gas meter to the service pipe.

 

 

 

If the gas supply for the boiler serves other appliances ensure that an adequate

supply is available both to the boiler and the other appliances when they are in use at the same time.

Pipe work must be of an adequate size. Pipes of a smaller size than the boiler inlet connection should not be used.

2.8WATER CONNECTIONS

FIG. 2.4

LEGEND:

A = Central Heating Flow

C = Gas Inlet

E= Central Heating Return

F= Safety Valve

G= Pump transportation screw (remove before igniting the boiler)

H= Automatic By-pass pipe

VIEW OF THE BOILER CONNECTIONS

 

 

 

E

 

D

 

 

 

A

 

B

C

 

 

 

F

 

 

 

FIG. 2.3

 

 

SC004A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Image 6
Contents Installation Instructions Type C Boilers Table of Contents General Instructions Installation Overall ViewReference Standards Clearances Overall DimensionsSiting the Appliance Mounting the Appliance Electrical ConnectionGAS Connection Water ConnectionsResidual Head of the Boiler Flue Connections Tower Flue Components80 mm Rffi Room Thermostat ConnectionElectrical Diagram On/Off SwitchGAS and Water Circuits 2 Port and 3 Port Valve Installations H.W. Storage CylinderModel Commissioning Domestic HOT Water Priority KITInitial Preparation Control Panel Removing the Front PanelInitial START-UP Combustion Analysis Fume Discharge MonitoringBoiler Safety Systems Draining the System Rffi GAS AdjustmentsMaintenance Changing the Type of GASTechnical Information Number 41-116-05

41-116-05 specifications

The Ariston 41-116-05 is an innovative and efficient appliance designed to meet modern home heating and comfort needs. As part of Ariston's extensive portfolio, this model embodies the brand's commitment to quality and sustainability.

One of the main features of the Ariston 41-116-05 is its advanced energy efficiency rating. It incorporates cutting-edge technology to optimize energy consumption, helping homeowners reduce their utility bills while minimizing their environmental impact. This aligns with the growing demand for eco-friendly heating solutions in today's market.

The heater is equipped with a powerful heating element, capable of quickly generating warmth even in larger spaces. Its robust performance ensures that rooms reach the desired temperature rapidly, providing comfort during cold weather conditions. The unit is designed with multiple heat settings, allowing users to customize the warmth level according to their preferences and specific needs.

Moreover, the Ariston 41-116-05 features an intuitive digital control panel. This user-friendly interface makes it easy for individuals to adjust settings, monitor energy consumption, and set timers for automatic operation. Some models also offer Wi-Fi connectivity, enabling users to control their heating remotely via a smartphone app. This feature is particularly beneficial for those who want to maintain a comfortable environment in their homes while controlling energy use.

Safety is another cornerstone of the Ariston 41-116-05’s design. The appliance is equipped with multiple safety mechanisms, including overheat protection and a tip-over switch. These features ensure that the unit operates safely and securely, providing peace of mind for homeowners.

In summary, the Ariston 41-116-05 is a modern appliance that combines efficiency, performance, and safety. Its exceptional energy-saving capabilities, user-friendly controls, and robust heating power make it an ideal choice for anyone seeking reliable home heating solutions. With its range of features and commitment to sustainability, the Ariston 41-116-05 stands out as a valuable addition to contemporary households, enhancing comfort while being mindful of the environment.