Bosch Appliances 24I RSF manual Spark electrode assembly

Page 21

6. Combustion Chamber Insulation.

Check that the electricity supply to the appliance is turned off. Drain the central heating circuit as described in Section 15.3(a). Remove the inner casing cover, fan, flue hood assembly, burner, and Gas to Water heat exchanger as described in Sections 14.3 (b, e and f), and 15.4 (5). Remove the fibre insulation pads from the combustion chamber side, rear, and front sections.

Fit the replacement pads in the reverse order taking care not to damage them.

Open the valves and fill and re-pressurise the system as described in Section 12.2.

7.Burner. See Fig. 31.

Check that the electricity and gas supplies to the appliance are turned off.

Remove the burner assembly as described in Section 14.3 (h).

Fit the replacement burner in the reverse order taking care not to damage the electrode leads.

8. Burner Injector. See Fig. 31.

Remove the burner as described in Section 14.3 (h). Unscrew the brass injector from the manifold.

Fit the replacement injector in the reverse order.

9. Spark Electrode Assembly. See Fig. 31a.

Remove the combustion chamber front as described in 14.3 (g) Carefully pull off the two electrode leads,

Undo the M4 extended nut and remove the spark electrode assembly from the burner.

Fit the replacement electrode in the reverse order, checking that the spark gap is 3.5 to 4.5mm.

Fig. 31a. Spark electrode assembly.

3.5-4.5mm

2.5-5mm

10. Flame Sensor. See Fig. 31.

Remove the burner as described in sections 14.3(h) and 15.4(8). Undo the M3 screw and remove the sense electrode from the burner.

Fit the replacement electrode in the reverse order, checking that the sense gap is 5 to 6mm.

11.Gas Valve. See Figs. 33. and 34.

Check that the electricity and gas supplies to the appliance are turned off.

Hinge down the control box assembly in the servicing position as described in Section 14.3(d).

Whilst supporting the valve unscrew the plug retaining screw and carefully pull off the electrical solenoid plug connection and the two modureg leads.

Undo the 8 manifold screws and remove the gas valve. See Fig. 34. Fit the replacement gas valve in the reverse order ensuring the ÒOÓ rings are correctly fitted.

Turn on the gas supply and check for soundness. To set the burner pressure. See Fig. 33.

The minimum and maximum burner pressures must be set after a new gas control has been fitted.

The maximum burner pressure must be set first, as any adjustment of the maximum pressure influences the minimum pressure setting.

Start the appliance in the domestic hot water mode as described in section 12.4. - Appliance Operation.

Adjust the maximum pressure adjustment screw on the gas valve to give a burner pressure of 13.6 mbar on natural gas, for propane the maximum pressure adjustment must be increased to maximum clockwise, this should give 33.0 - 35.0 mbar.

End the demand and reset the appliance by interrupting the mains electricity supply. (Otherwise there is a four minute anti- cycle delay at the end of a demand).

Restart the appliance in central heating mode and adjust the minimum adjustment screw on the gas valve to give a pressure of 1.0 mbar on natural gas or 3.5 mbar on propane. See Fig. 33.

After completing the adjustments, check the minimum and maximum pressures and re-adjust as necessary. Once this has been done the clear cap should be re-fitted to the adjuster and the retaining screw tightened. Coat the screw with paint or nail varnish to prevent user adjustment.

Fig. 27. Gas valve.

 

 

Maximum pressure

Main gas valve

 

adjuster

Minimum

Note: Clockwise to

connections

pressure

increase and anti-

(Black : blue : brown :

adjuster

clockwise to

green/yellow)

 

 

 

 

 

 

 

 

decrease the

 

 

 

 

pressure

Burner pressure

 

 

 

 

 

 

 

test point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inlet pressure test point

Modulating

Electrical connections Ð

modulator (Blue : Blue)

solenoid

 

12. Central Heating Sensor. See Fig. 34.

Check that the electricity supply to the appliance is turned off. Hinge the facia assembly in the servicing position as described in Section 14.3(c and d).

Carefully pull off the two leads from the sensor.

Pull off the sensor and spring retaining clip from the pipe.

Fit the replacement sensor in reverse order with a layer of heat sink compound between the faces. Refit the leads.

Fig. 34. Gas valve pump and air pressure

switch.

Air pressure switch

Top gas valve

Gas

Pump connecting tubes

connection (4 bolts)

valve

 

 

 

 

 

 

Red pipe

 

Central Heating

Pressure gauge

 

Gas valve

Sensor

connection

 

electrical

Lower pump

Air pressure

connections

connection

switch

21

Image 21
Contents These Instructions Apply in the UK only 24i RSFContents Installation RegulationsGeneral Information Safety Considerations General InstallationElectrical Supply PackingData Tables Siting The Appliance Appliance casing dimensions and required clearancesAir Supply Siting The FluePosition AIR from AIR Direct Terminal PositionOpen Vent System Sealed SystemRoom thermostat connections Hot Water SupplySafety Check ElectricalMains Supply Functional flow diagram Installing The Appliance Flue OptionsGeneral Fitting Appliance pipework connections AIR and Flue Duct Preparation and AssemblyStandard flue assembly Flue Bends Internal Fitting of the Duct AssemblyVertical Adapter Final InstallationCommissioning The Appliance SummaryAppliance and Central Heating System Preparation Programmer Appliance OperationCompletion of Commissioning PRE-SERVICE Inspection Inspection And ServiceInstructions To The User ServicingService of Components Dismantle the ApplianceTest the Appliance Component Access Replacement Of PartsComponent Replacement Draining the ApplianceSpark electrode assembly Water Flow Switch. Side View Gauze Filter Conversion InstructionsCentral Heating Mode Operational Flow DiagramsDomestic Hot Water Mode Fault Finding GO to Check F Check E GO to Check D Check CGO to Check O GO to Check KFaulty GO to Check L GO to CheckThermistor Check GO to Check G Check E GO to Check MGO to Check N APS OK White & BrownModulating Valve Check Component Parts List 1210 Bosch Group

24I RSF specifications

Bosch Appliances has long been a leader in the home appliance market, known for its innovation, reliability, and cutting-edge technology. One of the standout products from Bosch is the 24I RSF, a highly regarded model that exemplifies the brand’s commitment to quality and performance in home kitchen solutions.

The Bosch 24I RSF is a high-efficiency dishwasher designed to meet the needs of modern households. It features a sleek, compact design that is perfect for small kitchens or limited spaces without sacrificing capacity and functionality. With its 24-inch width, it seamlessly integrates into most kitchen environments while providing ample space for dishwashing needs.

One of the hallmark features of the Bosch 24I RSF is its incredible water and energy efficiency. Rated among the best in its class, this dishwasher uses sensors to detect how dirty the dishes are, automatically adjusting the wash cycle for optimal performance. This not only conserves water but also reduces energy consumption, making it an environmentally friendly choice for eco-conscious consumers.

The 24I RSF is also equipped with Bosch’s innovative PrecisionWash technology. This advanced system utilizes intelligent sensors to continually scan and adjust the wash cycle, ensuring all dishes are thoroughly cleaned, no matter their placement in the dishwasher. The powerful spray arms reach every corner and crevice, guaranteeing sparkling results every time.

In terms of user convenience, the Bosch 24I RSF comes with flexible loading options, including adjustable racks and a third rack for utensils, allowing users to efficiently optimize space. The Quiet operation, achieving noise levels as low as 44 decibels, makes it perfect for open-concept living spaces. Users can run dishwashing cycles even during quiet moments without disruption.

Another appealing characteristic of the Bosch 24I RSF is its simple user interface with a digital display, offering straightforward selections for the various wash cycles and options tailored to different types of loads. The self-cleaning filter system is an added convenience, reducing the need for maintenance.

Built with quality materials and robust engineering, the Bosch 24I RSF is not only reliable but also stylish, featuring a contemporary design that fits seamlessly into any kitchen decor. The combination of innovation, efficiency, and aesthetic appeal makes the Bosch 24I RSF an attractive choice for homeowners looking to elevate their kitchen experience. Its blend of features ensures exceptional cleaning performance while maintaining a commitment to sustainability, truly embodying the Bosch philosophy of creating appliances that improve everyday life.