Crown Boiler BWC150/225 installation instructions 12a Dimension L, Horizontal Terminal

Page 16

a)Cut a 5-1/2” diameter hole through the exterior wall at the planned location of the horizontal terminal.

b)Measure distance “L” from the outside surface of the exterior wall to the end of the last fitting as shown in Figure 1.12a.

c)Add 1-1/4” to distance “L”. Carefully mark this length on the pipe as shown in Figure 1.12b.

d)Remove the aluminum inner pipe from the terminal, by gently pulling on it from the male end. Set aside.

e)Cut the outer pipe only at the point marked in Step (c) using aviation shears, a hacksaw, or an abrasive wheel cutter. Be careful to cut the pipe square. De-burr the cut end with a file or emory cloth.

f)Reinstall the aluminum inner pipe in the terminal, making sure that the female end of this pipe is completely bottomed out over the aluminum male connection visible behind the air intake grill. Place a mark on the aluminum inner pipe 3/8” beyond the end of the outer pipe (Figure 1.12c). Use a fine tooth hacksaw or hand shears to cut the aluminum pipe and be careful to cut the pipe square (if necessary, the aluminum pipe can be removed from the terminal again for cutting). De-burr the cut edge of the aluminum pipe with a file or fine sandpaper.

g)Make a mark on the terminal section 1” from the cut end of the outer pipe as shown in Figure 1.12c.

h)Slip the terminal section through the wall from the outside. Pass the terminal through the inner wall plate and push into the last section of vent pipe until the mark made in Step (h) is not longer visible (Figure 1.12d). Secure the terminal to the last piece of pipe with three #10 x 1/2” sheet metal screws. Drill a 1/8 hole through both outer pipes to start these screws. Use a drill stop or other means to ensure that the drill bit does not penetrate more than 3/8” into the outer pipe. Do not use a sheet metal screw longer than 1/2”.

i)Slip the outer wall plate over the terminal and secure to the wall (Figure 1.12d). Apply a 1/8” bead of weather resistant RTV over the joint between the outside wall plate and the terminal. Secure the other wall plate to the inside wall.

FIGURE 1.12a: DIMENSION “L”, HORIZONTAL TERMINAL

FIGURE 1.12b: CUTTING OUTER PIPE OF HORIZONTAL TERMINAL

14

Image 16
Contents BWC Series Page Page Concentric Venting For BWC150 and BWC225 Page Summary of Horizontal Venting Options Horizontal Concentric Venting Vent Option 3,4 3c Positioning Vent Terminal Under Overhangs VENT/ AIR Intake Fitting Equivalent Length Vent Options 3,8 Concentric Vent Adapter Kit Installation Concentric Vent Adapter Assembly Assembly of Crown Concentric Venting 10 Cutting Straight Pipe 11a Joining Cuttable Pipe 12a Dimension L, Horizontal Terminal 12c Cutting Inner Pipe of Horizontal Terminal 13a Dimension H 13b Cutting Vertical Terminal 14 Chimney Chase Installation 15 Condensate Drain Line Assembly PN 980241 Rev BWC 12/07

BWC150/225 specifications

The Crown Boiler BWC150/225 is a highly efficient and reliable hydronic heating system designed for both residential and commercial applications. Known for its advanced engineering, this boiler delivers exceptional performance while adhering to strict emission standards. Its versatility and durability make it a popular choice among homeowners and professionals alike.

One of the key features of the BWC150/225 model is its dual-fuel capability, allowing the user to operate the boiler on either natural gas or propane. This flexibility not only ensures convenience but also enhances energy efficiency. The boiler is equipped with a powerful 150,000 BTU input capacity for the BWC150 variant and 225,000 BTU for the BWC225, making it capable of heating larger spaces efficiently.

The crown boiler utilizes a fire-tube heat exchanger, which is designed to maximize heat transfer while minimizing the amount of energy lost during operation. This innovative design allows for a higher thermal efficiency rate compared to traditional designs. With an efficiency rating exceeding 90%, the BWC series can significantly lower heating costs, making it an economically sound investment.

Additionally, the BWC model features a fully modulating gas valve that adjusts the heat output based on the demand. This system not only improves comfort by maintaining consistent temperatures but also reduces energy consumption. It is also designed with advanced safety features, including an integrated low-water cutoff and flame rollout protection, ensuring safe operation under various conditions.

Another noteworthy characteristic of the Crown Boiler BWC150/225 is its user-friendly digital control panel. The easy-to-read display provides users with vital information such as temperature settings and system diagnostics, simplifying both operation and maintenance. The compact design of the unit allows for easy installation in tight spaces, making it suitable for various home layouts.

In summary, the Crown Boiler BWC150/225 stands out for its advanced features, energy efficiency, and safety technologies. With its dual-fuel capability, fire-tube heat exchanger, and user-friendly interface, it is an optimal choice for those seeking a robust and reliable heating solution. Whether for residential or commercial purposes, this model offers the performance and convenience that modern users require.