Crown Boiler BWC150/225 installation instructions Vent Options 3,8

Page 10

TABLE 1.6a: CROWN CONCENTRIC 80/125 VENT COMPONENTS

(VENT OPTIONS 3,8)

 

 

 

USED ON

 

CROWN PN

DESCRIPTION

SIZE

VENT

COMMENTS

 

 

 

OPTION #

 

230527

90 DEGREE EL (STANDARD)

80/125mm

3,8

 

 

 

 

 

 

230528

90 DEGREE EL (SWEEP)

80/125mm

3,8

 

 

 

 

 

 

230526

45 DEGREE EL

80/125mm

3,8

 

 

 

 

 

 

230517

19 1/2” STRAIGHT

80/125mm

3,8

CAN BE CUT

 

 

 

 

 

230515

39” STRAIGHT

80/125mm

3,8

CAN BE CUT

 

 

 

 

 

230518

39” STRAIGHT

80/125mm

3,8

MAY NOT BE CUT

 

 

 

 

 

230519

78” STRAIGHT

80/125mm

3,8

MAY NOT BE CUT

 

 

 

 

 

230525

TELESCOPING STRAIGHT

80/125mm

3,8

ADJUSTABLE FROM 12-1/2” TO 16-1/2

 

 

 

 

 

230531

HORIZONTAL TERMINAL

80/125mm

3

 

 

 

 

 

 

230532

VERTICAL TERMINAL

80/125mm

8

(NOTE #1)

 

 

 

 

 

230533

FLAT ROOF FLASHING

80/125mm

8

 

 

 

 

 

 

230535

SLOPED ROOF FLASHING

80/125mm

8

(NOTE #2)

 

 

 

 

 

230530

SUPPORT ELBOW WITH

80/125mm

8

(NOTE #3)

CHIMNEY CHASE BRACKET

 

 

 

 

 

 

 

 

 

230536

SUPPORT BAND

80/125mm

3,8

 

 

 

 

 

 

Table 1.6a Notes:

1)Vertical terminal can be used with either of the roof flashings listed beneath it.

2)Sloped roof flashing suitable for roof angles between 25 and 45 degrees.

3)Used at base of vertical run inside unused masonry chimney.

TABLE 1.6b: CROWN CONCENTRIC100/150 VENT COMPONENTS

(VENT OPTIONS 8,9)

 

 

 

USED ON

 

CROWN PN

DESCRIPTION

SIZE

VENT

COMMENTS

 

 

 

OPTION #

 

 

 

 

 

 

230567

90 DEGREE EL (SWEEP)

100/150mm

4,9

 

 

 

 

 

 

230565

45 DEGREE EL

100/150mm

4,9

 

 

 

 

 

 

230560

19 1/2” STRAIGHT

100/150mm

4,9

CAN BE CUT

 

 

 

 

 

230562

39” STRAIGHT

100/150mm

4,9

CAN BE CUT

 

 

 

 

 

230561

39” STRAIGHT

100/150mm

4,9

MAY NOT BE CUT

 

 

 

 

 

230563

78” STRAIGHT

100/150mm

4,9

MAY NOT BE CUT

 

 

 

 

 

230564

TELESCOPING STRAIGHT

100/150mm

4,9

ADJUSTABLE FROM 12-1/2” TO 17-1/2

 

 

 

 

 

230569

HORIZONTAL TERMINAL

100/150mm

4

 

 

 

 

 

 

230570

VERTICAL TERMINAL

100/150mm

9

(NOTE #1)

 

 

 

 

 

230571

FLAT ROOF FLASHING

100/150mm

9

 

 

 

 

 

 

230572

SLOPED ROOF FLASHING

100/150mm

9

(NOTE #2)

 

 

 

 

 

230568

SUPPORT ELBOW WITH

100/150mm

9

(NOTE #3)

CHIMNEY CHASE BRACKET

 

 

 

 

 

 

 

 

 

230573

SUPPORT BAND

100/150mm

4,9

 

 

 

 

 

 

Table 1.6b Notes:

1)Vertical terminal can be used with either of the roof flashings listed beneath it.

2)Sloped roof flashing suitable for roof angles between 25 and 45 degrees.

3)Used at base of vertical run inside unused masonry chimney.

8

Image 10
Contents BWC Series Page Page Concentric Venting For BWC150 and BWC225 Page Summary of Horizontal Venting Options Horizontal Concentric Venting Vent Option 3,4 3c Positioning Vent Terminal Under Overhangs VENT/ AIR Intake Fitting Equivalent Length Vent Options 3,8 Concentric Vent Adapter Kit Installation Concentric Vent Adapter Assembly Assembly of Crown Concentric Venting 10 Cutting Straight Pipe 11a Joining Cuttable Pipe 12a Dimension L, Horizontal Terminal 12c Cutting Inner Pipe of Horizontal Terminal 13a Dimension H 13b Cutting Vertical Terminal 14 Chimney Chase Installation 15 Condensate Drain Line Assembly PN 980241 Rev BWC 12/07

BWC150/225 specifications

The Crown Boiler BWC150/225 is a highly efficient and reliable hydronic heating system designed for both residential and commercial applications. Known for its advanced engineering, this boiler delivers exceptional performance while adhering to strict emission standards. Its versatility and durability make it a popular choice among homeowners and professionals alike.

One of the key features of the BWC150/225 model is its dual-fuel capability, allowing the user to operate the boiler on either natural gas or propane. This flexibility not only ensures convenience but also enhances energy efficiency. The boiler is equipped with a powerful 150,000 BTU input capacity for the BWC150 variant and 225,000 BTU for the BWC225, making it capable of heating larger spaces efficiently.

The crown boiler utilizes a fire-tube heat exchanger, which is designed to maximize heat transfer while minimizing the amount of energy lost during operation. This innovative design allows for a higher thermal efficiency rate compared to traditional designs. With an efficiency rating exceeding 90%, the BWC series can significantly lower heating costs, making it an economically sound investment.

Additionally, the BWC model features a fully modulating gas valve that adjusts the heat output based on the demand. This system not only improves comfort by maintaining consistent temperatures but also reduces energy consumption. It is also designed with advanced safety features, including an integrated low-water cutoff and flame rollout protection, ensuring safe operation under various conditions.

Another noteworthy characteristic of the Crown Boiler BWC150/225 is its user-friendly digital control panel. The easy-to-read display provides users with vital information such as temperature settings and system diagnostics, simplifying both operation and maintenance. The compact design of the unit allows for easy installation in tight spaces, making it suitable for various home layouts.

In summary, the Crown Boiler BWC150/225 stands out for its advanced features, energy efficiency, and safety technologies. With its dual-fuel capability, fire-tube heat exchanger, and user-friendly interface, it is an optimal choice for those seeking a robust and reliable heating solution. Whether for residential or commercial purposes, this model offers the performance and convenience that modern users require.