To check and test hose connections:

1.Make certain the unit is not plugged into an electrical outlet.

2.Carefully push the power cord grommet through the hole in the back panel (see Figure 36).

Screws

 

Back

 

 

Panel

 

Grommet

 

 

Drain

Water

 

Connection

Power

Fitting

 

Cord

 

 

Figure 36

3. Remove 12 screws and back panel.

FittingWARNING

Back panel serves as a guard. DO NOT put your hands inside the ice maker cabinet or attempt to touch any components except the discharge tube during testing. Failure to follow this warning could result in serious personal injury or death.

4.Check that the clamps and hose connections are tight at the following areas (see Figure 37):

Discharge tube (A)

Drain tube (B)

Vent tube (C)

B

B

C

C

 

A

Back View

Side View

Figure 37

5.Place a suitable container beneath the pump’s discharge tube. (The bucket must be able to hold a minimum of one gallon.)

6.Plug the ice maker power cord into a properly grounded, polarized electrical outlet.

7.Verify pump operation by pouring one gallon of water into the ice storage bin of the ice maker. The pump should energize and pump the water into the container.

8.At this time, verify that all tube and clamp connections are tight and leak free.

9.Unplug unit power cord from electrical outlet.

10.Reinstall back panel.

To connect to drain:

1.Attach the 5/8-inch ID drain connection on the back of the unit to a 5/8-inch OD rigid tube, using a worm clamp.

2.Attach the other end of the rigid tube to your 5/8-inch ID drain line with a worm clamp.

3.Insulate the drain line, if necessary to prevent condensation. Go on to Water Supply Connection.

Locally-Installed Drain Pump

If a gravity drain connection is not possible, and you have not purchased the CLRCO2175 with factory-installed pump, we strongly recommend the use of the U-Line P60 drain pump. The U-Line P60 drain pump is available through your Dealer, or direct from U-Line with complete installation instructions. If a pump other than the U-Line P60 drain pump is to be used, it must meet the following specifications:

It must be UL listed and have a UL listed, 120 VAC, 3-wire grounded power cord.

It must have overall maximum outside dimensions of 8-3/4" wide x 5-3/4" deep x 7-3/4" high.

It must have a minimum flow rate of 1.5 gallons per minute at 10 feet of lift.

It must have a sealed sump which does not allow water leakage in the case of a power outage, restricted drain or pump failure.

It must have a check valve in the discharge line to prevent waste water return to the pump.

It must have an overflow protection control which will shut off power to the ice maker in the event of a pump failure.

It must have an operating temperature range of 50°F to 110°F (10°C to 40°C).

CLR2160, CLRCO2175

21