Temperature Control

Temperature Control

Checking Product Temperature

ULIN_0093_A

Figure 4

To check the actual product temperature, in refrigerator section only, insert an accurate thermometer into a plastic (non-breakable) bottle that is partially filled with water.

Tighten the bottle cap securely (Figure 4).

Place the bottle in the refrigerator area for 24 hours. Refrain from opening the unit during the testing period. After 24 hours, check the temperature of the water. If required, adjust the temperature control in a small increment (See ADJUSTING TEMPERATURE).

Factors which affect the internal temperatures of the cabinet include:

Temperature setting.

Ambient temperature where installed.

Number of times and length of time the door is opened and closed.

Installation in direct sunlight or near a heat source.

Interior Lighting

The interior of Model CLR2160 is not illuminated. The refrigerator section of Model CLRCO2175 is illuminated whenever the door is opened.

The LIGHT icon (Figure 3, 5) on the control panel is used to control an additional Model CLRCO2175 lighting function. The blackout/Sabbath mode (not Star K certified) will turn the interior light and display (Figure 3, 3) off.

To access the blackout/Sabbath mode (not Star K certified):

1.Touch and hold the LIGHT icon (Figure 3, 5) for ten seconds and release (the °F symbol will flash briefly at the end of the five second period).

2.The interior light and control display (Figure 3, 3) will go dark for 36 hours.

NOTE: Although the display will not be visible, the temperature controls in the unit remain active, and the interior temperature will be maintained.

3.To exit the blackout/Sabbath mode (not Star K certified) before the 36-hour period, repeat Step 1.

Electronic Control Panel

1

2

3

4

5

ULIN_0058_A

Figure 5

The electronic control with digital display (Figure 5) is configured to show a single temperature continuously. This set-point temperature is a base number used by the controller to maintain the temperature zone in your unit. The factory default set-point is 38°F. This set-point temperature is used as a gauge if further temperature adjustments are required.

Temperature Display Selection

U-Line products supplied for 110 VAC operation have temperatures displayed in a default Fahrenheit (°F) configuration (Figure 5, 3). Models supplied for 220 VAC operation have temperatures displayed in a default Celsius (°C) configuration.

The display can easily be adjusted for either type of temperature display. Press and hold the LIGHT icon (Figure 5, 5) and within five seconds press the COOLER icon (Figure 5, 4) three times to change the display as desired.

8

CLR2160, CLRCO2175

Page 8
Image 8
U-Line CLRCO2175, CLR2160 Temperature Control, Interior Lighting, Electronic Control Panel, Checking Product Temperature