U-Line manual Discard all ice produced in the first harvest, CLR2160, CLRCO2175

Models: CLR2160 CLRCO2175

1 28
Download 28 pages 10.67 Kb
Page 13
Image 13
•Discard all ice produced in the first harvest.

1

2

3

4

5

ULIN_0058_A

Figure 9

1.Turn the ice maker off (allowing any ice to melt off of the evaporator) as follows:

a.Touch and hold the ON/OFF button (Figure 9, 1).

b.The display (Figure 9, 3) will switch from ICE to OFF to confirm that the ice maker is off.

2.Remove all ice from the storage bin.

1

ULIN_0059_A

Figure 10

3. Remove inside front cover (Figure 10, 1).

1

ULIN_0060_A

Figure 11

4.Remove the overflow tube (Figure 11, 1) by lifting it up while using a slight back and forth motion to loosen

it from the drain hole. The water in the reservoir will flow down the drain.

5.Replace the overflow tube after all of the water has drained from the reservoir.

6.Start the cleaning cycle as follows:

a.Touch and hold the ON/OFF button (Figure 9, 1).

b.Touch and release the LIGHT button (Figure 9, 4) three times, then release the ON/OFF button (Figure 9, 1).

c.The display (Figure 9, 3) will show “CL” to confirm the beginning of the cleaning cycle.

7.When water begins to flow over the evaporator (approximately three minutes), add one package of U- Line Ice Machine cleaner to the water reservoir.

8.Reinstall inside front cover.

9.When the self-cleaning process stops (approximately 45 minutes) the unit will remain off for an additional 15 minutes. When clean cycle is completed, display will automatically switch back to set temperature and unit will run as normal operation.

10.Clean the storage bin (See INTERIOR CLEANING). Sanitize the bin with a solution of 1 tablespoon of bleach in 1 gallon of warm water. Rinse thoroughly with clean water.

11.To ensure that the drain system is working properly, pour 1 gallon of cool, fresh water into the ice bin. The water should drain freely. If your unit is equipped with a drain pump, it should drain the ice bin.

When ice production resumes, the water fill valve will energize, fill the water reservoir, and shut-off after three minutes. The compressor begins to operate and water flows over the evaporator assembly (ice cube tray). Initially, the water flow may not be uniform, causing uneven sized cubes or water to spill into the ice storage bin. This is a normal situation that will correct itself within the first 24 hours of operation.

IMPORTANT

Discard all ice produced in the first harvest.

Should power to the unit be interrupted during the self-clean cycle, it will be necessary to repeat the complete cleaning cycle after power is restored.

Inlet Screen

Interval - Every Twelve Months

The solenoid valve inlet screen must be cleaned at least once each year as follows:

1.Shut off the water at the main supply valve.

2.Pull the unit out to access the back panel.

3.Disconnect electrical power to the unit.

CLR2160, CLRCO2175

13

Page 13