U-Line CLRCO2175, CLR2160 manual Condenser Cleaning, Clear Ice Maker Maintenance

Models: CLR2160 CLRCO2175

1 28
Download 28 pages 10.67 Kb
Page 12
Image 12
Condenser Cleaning

To defrost:

1.Turn unit off.

2.Remove all products from the interior and prop the door in an open position (2 in. (5 cm) minimum).

3.Allow the frost to completely melt naturally. Clean the interior and all removed components using a mild non- abrasive detergent and warm water solution applied with a soft sponge or non-abrasive cloth. NOTE: DO NOT use any solvent-based or abrasive cleaners. They will discolor or damage the interior.

4.Dampen a soft sponge or non-abrasive cloth in clean water and wipe down the cabinet interior and removed components to remove any detergent residue. Rinse the sponge or cloth in clean water and repeat as necessary until the cabinet and components are clean.

5.When the interior is dry, turn unit back on.

Condenser Cleaning

Interval - Every Three Months

To maintain operational efficiency, keep the front grille free of dust and lint and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.

Clear Ice Maker MaintenanceWARNING

Disconnect electric power to the unit before cleaning the condenser.

To remove and replace the grille for access to the condenser fins, follow this procedure:

1

2

ULIN_0203_A

Figure 8

1.Disconnect electrical power to the unit.

2.Loosen two screws (Figure 8, 1) completely.

NOTE: Screws are held in the grille by o-ring retainers, and will not come free of the grille.

3. Remove the grille.

Manual backgroundWARNING

DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.

Manual backgroundCAUTION

DO NOT use any type of cleaner on the condenser unit.

4.Clean the condenser coil (Figure 8, 2) using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.

5.Position the grille to align the mounting screws with the holes in the cabinet.

6.Secure, but do not over-tighten both grille screws.

7.Reconnect power to the unit.

Clear Ice Maker Maintenance

Self-Cleaning Cycle

Interval - Every Six Months

To maintain operational efficiency, clean the unit every six months (depending on water conditions, more or less frequent cleaning may be necessary). If the ice maker requires more frequent cleaning, consult a qualified plumber to test the water quality and recommend appropriate treatment.

Manual backgroundWARNING

Wear rubber gloves and safety goggles and/or face shield when handling Ice Machine Cleaner.

Manual backgroundCAUTION

Use only U-Line Ice Machine Cleaner (P/N 41978, available from your dealer or direct from your local parts distributor. To locate a parts distributor near you, visit www.U-LineService.com.). It is a violation of federal law to use this solution in a manner inconsistent with its labeling. Use of any other cleaner can ruin the finish of the evaporator and will void the warranty. Read and understand all labels printed on the package before use.

U-Line Ice Machine Cleaner is used to remove lime scale and other mineral deposits. Refer to the following steps to initiate the self-cleaning cycle.

IMPORTANT

The Model CLRCO2175 refrigerator will not operate during the ice maker cleaning cycle. Remove all fresh food to prevent spoilage.

Model CLRCO2175 ice production after the first harvest may take longer after the cleaning cycle since restoring the refrigerator temperature will take precedence over ice production. Once the refrigerator reaches its set-point temperature, ice making will resume.

IMPORTANT

Never use anything to force ice from the evaporator. Damage may result.

12

CLR2160, CLRCO2175

Page 12
Image 12
U-Line CLRCO2175, CLR2160 manual Condenser Cleaning, Clear Ice Maker Maintenance