PROBLEM | POSSIBLE CAUSE | REMEDY | |
|
|
| |
Unit runs but produces very little ice. | Dirty condenser coils | Clean the condenser (See MAINTENANCE; CONDENSER | |
|
| CLEANING). | |
|
|
| |
| High air temperature around unit | Surrounding air temperature of over 90°F. Low ice | |
|
| production at high temperatures is normal. | |
|
|
| |
| Scale and mineral buildup in unit | Run unit through self cleaning cycle (See | |
|
| MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE. | |
|
|
| |
| Inadequate airflow at the front of | Remove items blocking airflow. | |
| the unit |
| |
|
|
| |
| Cleaning Cycle recently performed | Allow unit to reach the set temperature to produce ice | |
|
| normally. | |
|
|
| |
Poor ice quality (soft or unclear) | Unit is not level. | Level unit (See MAINTENANCE; LEVELING). | |
|
|
| |
| Poor incoming water quality | Consult a qualified plumber to test the water quality | |
|
| and recommend appropriate treatment. | |
|
|
| |
| Run unit through self cleaning cycle (See | ||
|
| MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE). | |
|
|
| |
Unit produces shallow or incomplete | Low water level | Check to see that overflow tube is fully seated. | |
cubes, or the ice fill pattern on the |
|
| |
Hot incoming water | Connect the unit to a cold water supply. | ||
evaporator is incomplete. | |||
|
| ||
| Incorrect incoming water pressure | Water pressure must be | |
|
|
| |
| Unit is not level. | Level unit (See MAINTENANCE; LEVELING). | |
|
|
| |
Ice is slow to release or does not | Run unit through self cleaning cycle (See | ||
release from the evaporator. |
| MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE). | |
|
|
| |
| Unit is not level. | Level the unit (See MAINTENANCE: LEVELING). | |
|
|
| |
| Low air temperature around unit | Surrounding air temperature must be at least 50°F. | |
|
|
| |
Ice storage bin full of water | Obstructed drain | Check to see that storage bin drain opening is free from | |
|
| obstruction and debris. | |
|
|
| |
Water leaking from under the unit | Supply line leaking | Tighten connection as required. | |
|
|
| |
| Fill tube leaking | Check connection at water valve outlet. | |
|
|
| |
| Bin drain leaking | Check integrity of bin drain hose and clamp. | |
|
|
|
CLR2160, CLRCO2175 | 25 |