PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

Unit runs but produces very little ice.

Dirty condenser coils

Clean the condenser (See MAINTENANCE; CONDENSER

 

 

CLEANING).

 

 

 

 

High air temperature around unit

Surrounding air temperature of over 90°F. Low ice

 

 

production at high temperatures is normal.

 

 

 

 

Scale and mineral buildup in unit

Run unit through self cleaning cycle (See

 

 

MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE.

 

 

 

 

Inadequate airflow at the front of

Remove items blocking airflow.

 

the unit

 

 

 

 

 

Cleaning Cycle recently performed

Allow unit to reach the set temperature to produce ice

 

 

normally.

 

 

 

Poor ice quality (soft or unclear)

Unit is not level.

Level unit (See MAINTENANCE; LEVELING).

 

 

 

 

Poor incoming water quality

Consult a qualified plumber to test the water quality

 

 

and recommend appropriate treatment.

 

 

 

 

Ice-making system is dirty.

Run unit through self cleaning cycle (See

 

 

MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE).

 

 

 

Unit produces shallow or incomplete

Low water level

Check to see that overflow tube is fully seated.

cubes, or the ice fill pattern on the

 

 

Hot incoming water

Connect the unit to a cold water supply.

evaporator is incomplete.

 

 

 

Incorrect incoming water pressure

Water pressure must be 20-120 psi.

 

 

 

 

Unit is not level.

Level unit (See MAINTENANCE; LEVELING).

 

 

 

Ice is slow to release or does not

Ice-making system is dirty.

Run unit through self cleaning cycle (See

release from the evaporator.

 

MAINTENANCE; ICE MAKER: SELF CLEANING CYCLE).

 

 

 

 

Unit is not level.

Level the unit (See MAINTENANCE: LEVELING).

 

 

 

 

Low air temperature around unit

Surrounding air temperature must be at least 50°F.

 

 

 

Ice storage bin full of water

Obstructed drain

Check to see that storage bin drain opening is free from

 

 

obstruction and debris.

 

 

 

Water leaking from under the unit

Supply line leaking

Tighten connection as required.

 

 

 

 

Fill tube leaking

Check connection at water valve outlet.

 

 

 

 

Bin drain leaking

Check integrity of bin drain hose and clamp.

 

 

 