Factory-Installed Drain Pump

Gravity Drain

 

 

Waste

 

Shut-Off

 

Valve

 

Cold

Hot

Water

Water

 

Waste

 

Figure 32

If using a Gravity Drain:

1.Attach the 5/8-inch ID drain connection on the back of the unit to a 5/8-inch OD rigid tube, using a worm clamp.

2.Attach the other end of the rigid tube to your 5/8-inch ID drain line with a worm clamp.

3.Insulate the drain line, if necessary to prevent condensation. Go on to Water Supply Connection.

Factory-Installed Drain Pump

If your drain line will run up to a stand pipe, disposal assembly or spigot assembly or does not otherwise meet the requirements for a Gravity Drain, you may have ordered the CLRCO2175 with a U-Line P60 Drain Pump. See Figures 33, 34 and 35 for typical installations requiring a Drain Pump. If you need to install a P60 Drain Pump into your unit, see Locally-Installed Drain Pump on Page 21.

Stand Pipe

 

 

Waste

 

Shut-Off

 

Valve

 

Cold

Hot

Water

Water

 

Waste

 

Figure 33

Disposal Assembly

 

Air Gap

 

(Optional Hook-Up)

 

 

Waste

 

Cold

Hot

Water

Water

 

 

Shut-Off

 

Valve

Figure 34

Spigot Assembly

 

Air Gap

 

(Optional Hook-Up)

 

 

Waste

 

Shut-Off

 

Valve

 

Cold

Hot

Water

Water

 

Figure 35

IMPORTANT

Before installing your U-Line CLRCO2175 with Factory- Installed U-Line P60 Pump, it is extremely important to check and test all hose connections at the drain pump. There is a possibility that hose connections may have loosened during shipment.

Manual backgroundWARNING