A.O. Smith GW/GWO-2500, GW/GWO-1000 warranty Suggested Specifications

Page 4

SUGGESTED SPECIFICATIONS

The hot water supply boiler(s) shall be an A.O. Smith Genesis Model GW _________ having an input rating of ________ BTU/hr,

and an output rating of ________ Btu/hr when fired with (Natural/Propane) _________ gas. The boiler shall bear the ASME “H”

stamp and shall be National Board registered (CRN in Canada) for 160 PSI working pressure. The boiler(s) shall be equipped with a factory installed 125 PSIG ASME Pressure Relief Valve.

The boiler(s) shall be design tested and certified to the ANSI Z21.13 standard and approved by the American and Canadian Gas Associations with a listed thermal efficiency of 84%.

The boiler’s copper fin tube heat exchanger shall be a horizontal, double row, two pass, 15-tube design. The lower first pass with 8 solid copper tubes, shall have integral extruded copper fins spaced at “5” fins per inch, the upper second pass with 7 solid copper tubes shall have “7” extruded copper fins per inch. The tubes shall be rolled into heavy (all Bronze “Standard” /or Cast Iron CoraShield lined ”optional”) ___________________headers. The ASME approved bolted split headers must have a removable

faceplate that allows full access and inspection of the tubes and internal header surfaces. Non-removable one-piece headers, with small inspection plugs, shall not be acceptable.

The heat exchanger shall bear a 5-year manufacturer’s limited warranty against failure. The heat exchanger shall be immune to thermal shock.

The Boiler(s) shall be provided with the factory sized, integrally rear header mounted, pre-wired, bronze fitted, factory installed pump. The pump shall be controlled by the boiler’s Dia-Scan II control and include an adjustable time delay, that allows the removal of useable residual heat from the combustion chamber and cools the boiler to an equal system temperature during the stand-by cycle.

The combustion chamber shall be fully lined with lightweight, high temperature ceramic fiber insulation, rated to 2,300°F (1260°C). The jacket panels shall be powder coated with a baked-on finish, which is suitable for outdoor service. The jacket shall be of tight construction, and weather and water-resistant.

The boiler shall employ a fan induced premixed multi-burner system firing into a pressurized combustion chamber. The “4509” stainless steel/titanium alloy burners shall be fired using Pre-Jet gas orifices that provide precise gas to air mixture for clean combustion and low NOx operation. The pre-Jet gas orifices shall be self-adjusting for altitude, from sea level to 6,000 feet (1,830m). The boiler(s) shall be capable of meeting or exceeding the current national, state, and local air quality regulations for low NOx.

All electrical boiler functions shall be controlled, operated, and monitored by a Dia-Scan II microprocessor-based control. The Dia- Scan II control shall provide (three “GW-1000 thru GW-1500”/four “GW-1850 thru GW-2500) _____ stage operation. Each stage

shall be adjustable by the operator to allow the boiler to be adjusted to suit the application and maximize system/boiler efficiency and operation. The microprocessor shall control the boiler temperature and be accurate to within plus or minus 1°F. The hot surface ignition system shall employ a separate flame sensor for each stage to provide maximum safety. The microprocessor- based boiler control shall be tested to ANSI standards and approved by both UL and AGA/CSA.

The boiler shall be supplied with a remote tank thermistor for sensing and controlling the storage tank temperature up to 1,000 feet (300m) away by the Dia-Scan II boiler control. Alternate 24V contacts shall also be provided to allow the boiler to be controlled by energy management systems and/or multi-boiler controllers.

The microprocessor-based control shall be self-diagnostic and provide 25 LED’s that indicate current operating and fault status. In addition to the LED’s, a digital LED enunciator shall provide numerical read outs of inlet/outlet, inlet/outlet differential, set point and set point differential temperatures; along with additional numerical failure codes.

Factory mounted and wired flow, blower prover, and blocked flue switches shall be provided. The gas train shall meet or exceed the requirements of ANSI Z21. 13 and include gas pressure regulator, manual gas cock, redundant safety gas valve, operating control valve, and plugged pressure test tapings.

The boiler(s) shall be AGA/CSA approved for direct horizontal through the wall venting, or direct vertical venting; in addition to conventional sidewall or conventional vertical venting. The boiler(s) must be field convertible from top mounted venting to rear mounted venting.

For maximum floor space optimization, the boiler(s) will have the option of being stacked directly one above the other using a factory designed Stack-Rack as provided by the manufacturer. Boilers with top only vent outlets that cannot be stacked directly one above the other are not acceptable.

A.O. Smith Water Products Co., Inc. On Line

www.hotwater.com

For Technical Information and

Automated Fax Service,

Phone: 800-527-1953

A. O. Smith

Water Products Company

Ashland City, TN

A Division of A. O. Smith Corporation

A. O. Smith Corporation reserves the right to make product changes or improvements at any time without notice.

A 012.18

© A. O. Smith Corp., 2003

Printed in U.S.A.

Image 4
Contents Features Limited Warranty Outline012.16 Outdoor Models ModelSuggested Specifications

GW/GWO-1000, GW/GWO-2500 specifications

A.O. Smith is a renowned brand in the water heating industry, known for its innovative and energy-efficient solutions. Among its notable product offerings are the GW/GWO-2500 and GW/GWO-1000 models, which cater to diverse needs in residential and commercial applications.

The A.O. Smith GW/GWO-2500 is a high-capacity water heater designed for large-scale demands. With a robust heating capacity, it can efficiently supply hot water for applications such as commercial kitchens, larger residential properties, and various industrial uses. This model features advanced insulation technology to minimize heat loss, ensuring optimal efficiency. Its high recovery rate means that it can replenish hot water quickly, making it ideal for establishments that require a continuous supply.

Similarly, the GW/GWO-1000 is tailored for smaller applications but does not compromise on performance. This model offers a balance of efficiency and productivity, making it suitable for smaller commercial environments or residential homes with moderate hot water needs. Like the GW/GWO-2500, it incorporates A.O. Smith’s advanced insulation to improve energy savings, offering a competitive performance while keeping energy costs low.

Both models are equipped with durable stainless-steel tanks, ensuring longevity and resistance to corrosion. They also feature user-friendly digital controls, allowing for easy temperature adjustments and monitoring. Safety is paramount, and these water heaters come with multiple safety features, including temperature and pressure relief valves, ensuring peace of mind for users.

One of the standout technologies in these models is the integration of intelligent diagnostics, which enables the system to self-check various components. This feature allows for early detection of potential issues, resulting in proactive maintenance and reduced downtime. Additionally, both models are designed to be environmentally friendly, complying with strict energy efficiency standards, which helps reduce the carbon footprint.

In summary, A.O. Smith's GW/GWO-2500 and GW/GWO-1000 water heaters exemplify quality and efficiency. Their innovative features, robust construction, and user-friendly designs make them excellent choices for a variety of hot water needs, from residential to large industrial applications. With A.O. Smith's commitment to quality and innovation, users can trust these models to deliver reliable performance for years to come.