Chapter 5: Preparing for Router Installation

CAUTION: To comply with intrabuilding lightning/surge requirements, intrabuilding wiring must be shielded, and the shield for the wiring must be grounded at both ends.

Router Power Requirements

Table 54 on page 109 and Table 55 on page 109 list the AC and DC power system electrical specifications for J-series Services Routers.

Table 54: AC and DC Power System Electrical Specifications for J2320 and J2350 Routers

Item

Specification

AC input voltage

100 to 240 VAC nominal

AC input line frequency

50 to 60 Hz

AC system current rating

J2320 Services Routers: 3.2 A to 1.3 A

 

J2350 Services Routers: 3.5 A to 1.5 A

DC input voltage

–48 to –60 VDC operating range

DC system current rating

7.2 A

Table 55: AC and DC Power System Electrical Specifications for J4350 and J6350 Routers

Item

Specification

AC input voltage

100 to 240 VAC nominal

AC input line frequency

50 to 60 Hz

AC system current rating

J4350 Services Routers: 6 A

 

J6350 Services Routers: 8 A

DC input voltage

–48 to –60 VDC operating range

DC system current rating

20 A

AC Power, Connection, and Power Cord Specifications

NOTE: The AC power cord for the Services Router is intended for use with the router only and not for any other use.

Power Guidelines, Requirements, and Specifications 109

Page 131
Image 131
Juniper Networks J4350, J6350 manual Router Power Requirements, AC Power, Connection, and Power Cord Specifications