J2320, J2350, J4350, and J6350 Services Router Getting Started Guide

user@host# set chassis fpc 2 offline

If the power and heat tokens no longer exceed the maximum, the PIMs that were placed offline by J-series power management are brought online automatically.

Use the set chassis disable-power-managementcommand to disable J-series power management:

user@host# set chassis disable-power-management

CAUTION: Use extreme caution when disabling J-series power management. To prevent equipment damage, do not install a combination of PIMs that exceeds the power or heat capacity of your router when J-series power management is disabled.

The set chassis disable-power-managementcommand brings the offline PIMs online automatically.

To reenable J-series power management, remove the set chassis disable-power-managementcommand from the configuration. For detailed information about the set chassis fpc offline and set chassis disable-power-managementcommands, see the JUNOS System Basics Configuration Guide.

Contacting the Juniper Networks Technical Assistance Center

If you need assistance while troubleshooting a Services Router, open a support case using the Case Manager link at http://www.juniper.net/support/, or call 1-888-314-JTAC (within the United States) or 1-408-745-9500 (from outside the United States). For more information, see “Contacting Customer Support and Returning Hardware” on page 213.