INSTALLATION

MULTIFUEL GRATE

GRATE

The grates in the Acorn Multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb". All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "H" sitting on the high sections of the comb, and the ends marked "L" sitting on the low sections.

ASSEMBLING THE GRATE

To assemble the grate, fit bars to low sections of the comb first, inserting end marked "H" into rear channel with groove on underside of bar located on upstand tab, and then lowering end marked "L" onto the low section of the comb. The upper bar is fitted in a similar manner, but with the end marked "L" inserted in the rear channel, and the end marked "H" seated on the high section of the comb.

GRATE BAR REPLACEMENT

After extended use it may be necessary to replace some of the grate bars.

Periodic inspection of the bars is recommended and the removal of any nails or wire that may be present after burning wood. All the grate bars in each appliance are identical and can easily be lifted out after removal of the fuel retainers. Remove damaged grate bars and replace with casting of the same type, fitting as per instructions above. (Check Identification letters on the casting when reordering).

10

Acorn Multifuel Stoves

Image 10
Contents Acorn Copyright Contents Petroleum Coke Introduction Safety Principle of the FireCheck List AFS009ATechnical Data AcornCombustible Materials Installation General PrecautionsHearth AIR for Combustion HandlingFitting the Optional Floor Fixing KIT Installation Firebox Liner PanelsRemoval of the Throat Plate Grate Installation Multifuel GrateGrate BAR Replacement Assembling the GrateInstallation Fitting the Flue Outlet and HOT Plate Flues and ChimneysInstallation For ALL AppliancesInstallation Typical Rear Flue Outlet Installation Typical Metal Insulated Chimney System Water Connections Installation Instructions ADD in BoilersFitting Final Check Installation InstructionsAIR Inlet Controls Multi Purpose Operating Tool Operating InstructionsDisassemble Airwash Fire Door GlassFuel Types Adjusting the Door HingesRecommended Reading Burning Wood Lighting the FireExtended Burning Mixed FuelsDE Ashing OVER-FIRINGASH Removal ClinkerChimney Sweeping Annual MaintenanceCleaning Door GlassChecklist Final Check ListParts List Part Description Visual Aid AcornParts List Parts List Invalidate the Appliance Warranty GuaranteeCustomer Registration Service Record Date of Visit Company Work Carried Out Signature’ve checked it and it’s O.K Final Factory Check List
Related manuals
Manual 36 pages 2.85 Kb