1F85RF-275 Thermostat and Wireless Remote Sensor Kit
Automatic Heat/Cool Changeover Thermostat for Single Stage/
Installation and Operating Instructions for Model:
|
|
|
Model | Programming Choices | |
5/1/1 Day | ||
Wireless Remote Sensor |
APPLICATIONS
THERMOSTAT APPLICATION GUIDE
Description |
|
|
Heat Pump (No Auxiliary or Emergency Heat) | Yes | |
|
|
|
Heat Pump (with Auxiliary or Emergency Heat) | Yes | |
|
|
|
Standard Heat & Cooling Systems | Yes | |
|
| |
Yes |
| |
One Call for Heat or Cool |
|
|
|
|
|
Standard Heat Only Systems | Yes | |
|
| |
Millivolt Heat Only Systems – Floor or Wall Furnaces | No |
|
|
|
|
Standard Central Air Conditioning | Yes | |
|
|
|
Gas or Oil Heat | Yes | |
|
| |
Electric Furnace |
| |
Yes |
| |
Hydronic (Hot Water) Zone Heat – 2 Wires | * Yes | |
|
|
|
Hydronic (Hot Water) Zone Heat – 3 Wires | No |
* Common Connection Required
Wireless Remote Sensor
SPECIFICATIONS
Thermostat:
Electrical Ratings | 20 to 30 VAC 50/60 Hz |
| 0.2 to 0.6 Amps per Load |
| (Y1, E/W1, G) |
| 1.5 Amps (Y2, W2, O, B |
| Load per terminal) |
| 1.5 Amps Max |
| (All terminals combined) |
Setpoint Range | 45 to 90°F (7 to 32°C) |
Rated Differential (Single Stage) ... | Heat 0.6° or 1.5°F, Cool 1.2°F |
Rated Differential | Heat 0.6° or 1.5°F, Cool 1.2°F |
Rated Differential (Heat Pump) | Heat & Cool 0.75° or 1.2°F |
Operating Ambient | 32 to +105°F (0 to +41°C) |
Operating Humidity | 90% |
Shipping Temp. Range | |
Thermostat Dimensions |
Remote Sensor:
This device complies with Part 15 of the FCC Rules, Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Maximum Wireless Remote Sensors | 1 indoor, 1 outdoor |
Operating Range | 45 to 90°F (7 to 32°C) |
Operating Humidity Range | 0 to 90% RH |
| |
Dimensions | |
* Max. Distance from Thermostat | 200 feet |
*Distance shown is for a typical application. Distances may vary in some applications because obstacles that block the signal path may affect the strength of the signal.
!CAUTION
To prevent electrical shock and/or equipment dam- age, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
|
|
Index | Page |
Installation | 2 |
Wiring Connections | 3 |
Thermostat/Sensor Quick Reference | 4 |
Installer Configuration Menus | 6 |
Operating Your Thermostat and Sensor | 9 |
Programming | 13 |
Troubleshooting | 14 |
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this prod- uct may replace a product which contains mercury.
Mercury and products containing mercury must not be dis- carded in household trash. Do not touch any spilled mercury. Wearing
2895 Harrison Street
Batesville, AR 72501
PART NO.
Replaces | |
| 0745 |