THERMOSTAT CONFIGURATION MENU
INSTALLER/CONFIGURATION MENU
Press the System button until OFF is displayed, then press the and simultaneously
| Press | Displayed | Press | or |
|
Step | Button(s) | (Factory Default) | to select | Comments | |
|
|
|
|
| |
1 | System | MS2 | SS1, HP2, HP1 | Selects Single stage, | |
|
|
|
|
| (Single stage or |
|
|
|
|
| |
2 | System | LER (OFF) | LER (ON) | Selects learn mode OFF or ON | |
|
|
|
|
| |
3 | System | OUTSIDE(OFF) | OUTSIDE(ON) | Selects OUTSIDE sensor OFF or ON | |
|
|
|
|
| |
4 | System | REMOTE(OFF) | REMOTE(ON) | Selects REMOTE (indoor) sensor OFF or ON | |
|
|
|
|
| |
5 | System | LOCAL (ON) | LOCAL (OFF) | Selects LOCAL sensor ON or OFF | |
6 | System | CH (0) | 1 to 9 | Select Receiver frequency offset | |
7 | System | PRG 4 | PRG 0, PRG 2 | Selects Programmable Periods | |
8 | System | EMR (ON) | EMR (OFF) | Selects Energy Management Recovery OFF or ON | |
|
|
|
|
|
|
9 | System | CR HEAT COOL (FA) |
| SL | Selects Fast or Slow cycle selection |
10 | System | CL (OFF) | CL (ON) | Selects Compressor Lockout CL OFF or ON | |
11 | System | CdL (ON) | CdL (OFF) | Selects Backlight Display ON or OFF | |
|
|
|
|
| |
12 | System | FA HEAT COOL (ON) | FA HEAT COOL (OFF) | Selects Fast Second Stage ON or OFF | |
|
|
|
|
| |
13 | System | 0 FLTR | Selects filter replacement run time.0 =Disabled | ||
|
|
|
|
| |
14 | System | 0 F | 4 LO to 4 HI | Selects Temperature Display Adjustment 4 LO 4 HI | |
|
| (Room Temperature) |
|
|
|
|
|
|
|
| |
15 | System | 4:00 HOLD | 0:00 to 8:00 | Selects Temporary Program Override Time | |
|
|
| (Increments of 15 minutes) | 0:00 =Disabled | |
|
|
|
|
|
|
16 | System | F |
| C | For C selection |
|
|
|
|
| Selects temperature display as F° or C° |
|
|
|
|
| |
17 | System | LR HEAT (90) | LR 62 to LR 89 | Selects Limited HEAT range | |
|
|
|
|
| |
18 | System | LR COOL (45) | LR 46 to LR 82 | Selects Limited COOL range | |
|
|
|
|
| |
19 | System | CA (OFF) | CA (ON) | Selects Comfort Alert Lock | |
|
|
|
|
| |
20 | System | OFF LOCK | ON LOCK | Selects Buttonpad Lockout | |
21 |
| 0 00 LOCK | 001 to 999 | Selects Buttonpad lockout combination number | |
|
|
|
|
| Press System to set code |
|
|
|
|
|
|
| Run |
|
|
| Returns to the OFF mode |
The configuration menu allows you to set certain thermostat operating characteristics to your system or personal require- ments.
Set SYSTEM button to OFF, then simultaneously press and to enter configuration menu. The display will show the first item in the configuration menu.
The configuration menu table summarizes the configuration options. An explanation of each option follows.
Press SYSTEM to change to the next menu item. To exit the menu and return to the program operation, press RUN. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.
1)Single Stage,
System Type | Select Option |
Single Stage Heat/Cool systems | SS1 |
MS2 | |
Heat Pump system, 1 compressor or 1 speed compressor | HP1 |
Heat Pump systems, 2 compressors or 2 speed compressor | HP2 |
The thermostat is factory defaulted to MS2. To select a different option, press the or key to scroll through the choices.
2)Select Learn Mode On or Off – Selecting LER On enables the learn mode of the thermostat receiver. Your thermostat is configured at the factory to recognize the remote sensor shipped with it. The Learn Mode Option is used only when required as described in Learn Mode Option.
3)Selects OUTSIDE sensor OFF or ON – Selecting OUTSIDE ON enables the thermostat to read a wireless outdoor temperature sensor that has been configured for Sensor O in the Learn Mode. This allows the thermostat to display the outdoor temperature reading.
4)Selects REMOTE sensor OFF or ON – Selecting REMOTE ON allows the thermostat to sense an indoor remote sensor that has been
5)Selects LOCAL sensor ON or OFF – Selecting LOCAL ON allows the thermostat to use the onboard temperature sensor exclusively or for averaging with the remote sensor readings. To control temperature using only the
indoor remote sensor temperature(s), use the or buttons to select LOCAL OFF.
6)Select Receiver frequency offset – This option allows you to select a different channel than the factory default for communication between the thermostat and remote sensor. Note: If a different channel is selected on the thermostat it must also be changed to the same
6