TROUBLESHOOTING
Symptom | Possible Cause | Corrective Action |
| ||
|
|
| |||
Furnace | 1. The location of the thermostat and/or | Digital thermostats normally provide precise | |||
(Air Conditioner) | the size of the Heating System may | temperature control and may cycle faster than some | |||
Cycles Too Fast | be influencing the cycle rate. | older mechanical models. A faster cycle rate means | |||
or Too Slow (narrow or |
| the unit turns on and off more frequently but runs for | |||
wide temperature swing) |
| a shorter time so there is no increase in energy use. | |||
|
| If you would like to increase the cycle time, choose | |||
|
| SL for slow cycle in the menu, step 4. If an accept- | |||
|
| able cycle rate is not achieved as received or by | |||
|
| choosing slow cycle, contact a local service person | |||
|
| for additional suggestions. |
| ||
|
|
| |||
Thermostat Setting & | 1. Thermostat thermometer setting | The thermometer can be adjusted +/- 3 degrees. | |||
Thermostat Thermometer | requires adjustment. | See Temperature Display Adjustment in the | |||
Disagree |
| Configuration Menu section. |
| ||
|
|
| |||
Blank Display and/or | 1. Voltage spike or static discharge. | Use the Reset Operation at top of previous page. | |||
Keypad Not Responding |
|
|
|
|
|
|
|
| |||
Heat Setpoint will | 1. The desired setpoint conflicts with the | Change system mode to COOL. Raise the Cool | |||
not Respond to the | setpoint of the COOL mode. | setpoint. Return to HEAT mode and set desired | |||
Temperature Up Key |
| temperature. |
|
| |
|
|
| |||
Cool Setpoint will | 1. The desired setpoint conflicts with the | Change system mode to HEAT. Lower the Heat | |||
not Respond to the | setpoint of the HEAT mode. | setpoint. Return to COOL mode and set desired | |||
Temperature Down Key |
| temperature. |
|
| |
|
|
|
| ||
Forgot Keypad |
| With the thermostat in any mode, press | and | ||
Lockout Code |
| at the same time to enter the configuration menu at | |||
|
| the point where the lockout code is to be entered. | |||
|
| Press | and | and SYSTEM button at the same | |
|
| time to reset the lockout code, unlock the keypad. | |||
|
|
| |||
Why won't my 2nd or |
| Your thermostat is designed to determine the | |||
3rd stage come on? |
| optimum time to activate the second stage. Simply | |||
|
| raising the temperature in heating or lowering it in | |||
|
| cooling will not always force the thermostat to bring | |||
|
| the second stage on quickly. There is a time delay | |||
|
| from | |||
|
| the first stage of the system. |
| ||
|
|
|
|
|
|