INSTALLATION
REMOVE OLD THERMOSTAT
1.Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.
2.Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.
3.Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat.
4.Disconnect the wires from old thermostat one at a time. DO
NOT LET WIRES FALL BACK INTO THE WALL.
5.Install new thermostat using the following procedures.
ELECTRIC HEAT OR SINGLE-STAGE HEAT
PUMP SYSTEMS
Read entire paragraph before setting electric heat switch. If you are unsure of your application, contact a qualified serviceperson.
If you have a
If you must move the switch to the “ELECTRIC” position (to the left), use a small screwdriver or pencil.
ATTACH THERMOSTAT BASE TO WALL
1. | Remove the packing material from the thermostat. Gently |
| pull the cover straight off the base. Forcing or prying on the |
| thermostat will cause damage to the unit. If necessary, move |
| the electric heat switch (see ELECTRIC HEAT SYSTEMS, |
| above). |
2. | Connect wires beneath terminal screws on base using |
| appropriate wiring schematic (see figs. 3 through 10). |
3. | Place base over hole in wall and mark mounting hole |
| locations on wall using base as a template. |
4. | Move base out of the way. Drill mounting holes. |
5. | Fasten base loosely to wall, as shown in fig. 2, using two |
| mounting screws. Place a level against bottom of base, |
| adjust until level, and then tighten screws. (Leveling is for |
| appearance only and will not affect thermostat operation.) If |
| you are using existing mounting holes, or if holes drilled are |
| too large and do not allow you to tighten base snugly, use |
| plastic screw anchors to secure subbase. |
6. | Push excess wire into wall and plug hole with a |
| material (such as fiberglass insulation) to prevent drafts from |
ELECTRIC GAS
Electric/Gas switch
Figure 1. Back of thermostat base
Alkaline batteries (3 "AA"– install "+" ends to the left)
Screw anchors
W | RH |
RC |
|
G | B |
Y | O |
Mounting
holes
Figure 2. Thermostat base
THERMOSTAT
B O Y G | W RC RH |
SYSTEM
Heating |
|
|
|
System |
|
| 24 VAC Transformer |
|
|
| |
|
|
| or |
|
|
| Thermopile |
|
|
|
|
Figure 3. Typical wiring diagram for heating only,
2-wire, single transformer systems or millivolt systems
affecting thermostat operation. |
BATTERY LOCATION
This thermostat requires 3 “AA” alkaline batteries to operate. Batteries are installed in the thermostat at the factory with a battery tag to prevent power drainage. You must remove the battery tag to engage the batteries and provide power to the thermostat.
If the word BATTERY is displayed, the batteries are low and should be replaced with fresh “AA” Energizer® alkaline batteries. To replace batteries, install the batteries along the top of the
Thermostat
R W
| NOTE |
| ||
Jumper wire must be | ||||
Primary Control | ||||
added between R and B | ||||
(located at furnace) | ||||
terminals on the | primary | |||
control (jumper | wire not | B | ||
provided with thermostat). |
W |
|
R |
|
Add jumper wire | Furnace |
| |
(not provided with thermostat) |
|
base (see fig. 2). The batteries must be installed with the positive
(+) ends to the left.
Figure 4. Typical wiring diagram for 3-wire SERIES 10 heating systems