White Rodgers 1F83-0422 Thermostat, 1F85-0422 Second Stage Time Delay, Set Current Time and Date

Page 7

OPERATING YOUR THERMOSTAT

Second Stage Time Delay

Your thermostat is designed to determine the optimum time to activate the second stage. Simply raising the temperature in heating or lowering it in cooling will not always force the thermostat to bring the second stage on quickly. There is a time delay from 0-30 minutes depending on the performance of the first stage of the system.

EXAMPLE: For the last 2 hours the thermostat is set on 70° and the room temperature is 70° with the equipment using only the first stage of heat. Since the equipment is keeping the temperature within 1° of setpoint, the thermostat will

IMPORTANT!

delay second stage for a longer time if you manually raise the temperature or if the room temperature quickly changes. Once the second stage comes on, it will come on sooner the next time there is a difference between the setpoint and the room temperature. The net effect of the staging program is that when the first stage is capable of making temperature the second stage will delay longer. When the thermostat calculates that first stage cannot make temperature in a reasonable time, the second stage will come on sooner. This built in function automatically optimizes the use of additional stages of heat or cool.

PROGRAMMING (For Programmable Model Only)

Set Current Time and Date

1)Press MENU and then TIME button once. The display will show the hour only.

2)Press and hold either the or key until you reach the correct hour and AM/PM designation (AM begins at midnight, PM begins at noon).

3)Press TIME once again. The display window will show the minutes only.

4)Press and hold either the or key until you reach the correct minutes.

5)Additional presses of TIME will advance the display to

show the year, month and date of month. Press the

or key to change the display to the correct setting for each.

6)Press RUN SCHED to exit the TIME mode.

Enter the Heating Program

1)Press SYSTEM button to select “Heat” in the system switch area indicating the active mode being pro- grammed.

2)Press the MENU button and then press SCHEDULE.

3)The top of the display will show the day(s) being pro- grammed. The time and temperature (flashing) are also displayed. “1” will also be displayed to indicate the period.

Energy Saving Factory Pre-Program

The 1F85-0422 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermo-

4)Press or key to change the temperature to your selected temperature for the 1st heating period.

5)Press TIME button, time will flash.

6)Press or key to adjust the start time for the 1st period.

7)The time will change in 15 minute increments.

8)After you have set the time and the temperature for

the period to begin, press SCHEDULE to advance to the next program period.

9)Repeat steps 2 through 8 until all of the program times and temperatures are set for all program periods on that day.

10)Press SCHEDULE to the next day and repeat steps 2 through 9.

11)When programming is complete and all of the times and temperatures match your desired heating schedule, press RUN SCHEDULE. The thermostat will now run your program.

Enter the Cooling Program

1)Press SYSTEM button to select “Cool” in the system switch area indicating the active mode being pro- grammed.

2)Follow Enter Heating Program instructions for entering cooling times and temperatures.

stat clock and press the RUN SCHED button.

The table below shows the factory set heating and cooling schedule for all days of the week.

 

Wake Up

Leave For Work

Return Home

Go To Bed

 

(Period 1)

(Period 2)

(Period 3)

(Period 4)

 

 

 

 

 

 

 

 

 

Heating

6:00 AM

70°F

8:00 AM

62°F

5:00 PM

70°F

10:00 PM

62°F

Program

 

 

 

 

 

 

 

 

 

Cooling

6:00 AM

75°F

8:00 AM

83°F

5:00 PM

75°F

10:00 PM

78°F

Program

 

 

 

 

 

 

 

 

 

7

Image 7
Contents 1F83-0422 Thermostat Save these instructions for future use1F85-0422 1F83-0422Remove Old Thermostat InstallationWiring Connections Installing New ThermostatThermostat Quick Reference Programming and Configuration ItemsHome Screen Description Press INSTALLER/CONFIGURATION Menu 1F85 1F83 Or key Select Temperature Display Adjustment 4 LO to 4 HIOperating Your Thermostat Choose the Fan Setting Auto or OnChoose the System Setting Heat, Off, Cool, Auto, Emer Manual Operation for Non-Programmable ModeEnergy Saving Factory Pre-Program Second Stage Time DelaySet Current Time and Date Enter the Heating ProgramWorksheet for Re-Programming 5+2 Day and 5+1+1 Day Program TroubleshootingProgramming Planning Your Program ImportantReset Operation Symptom Possible Cause Correction ActionPage Page Homeowner Help Line
Related manuals