White Rodgers 1F83-0422 Thermostat Symptom Possible Cause Correction Action, Reset Operation

Page 9

Reset Operation

Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not

TROUBLESHOOTING

function correctly contact your heating/cooling service person or place of purchase.

Note: Be sure to review the installer configuration menu settings.

To reset the programming, clock and configuration settings,

press and and the FAN button simultaneously. The thermostat should go blank and then all segments will be displayed momentarily.

Symptom

Possible Cause

Correction Action

 

 

 

 

No Heat/No Cool/No Fan

1.

Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2.

Furnace power switch to OFF.

Turn switch to ON.

 

3.

Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

 

panel loose or not properly installed.

interlock or door switch.

 

4.

Loose connection to thermostat or

Tighten connections.

 

 

system.

 

 

 

 

 

No Heat

1.

Pilot light not lit.

Re-light pilot.

 

2.

Furnace Lock-Out Condition. Heat

Many furnaces have safety devices that shut down when

 

 

may also be intermittent.

a lock-out condition occurs. If the heat works intermittently

 

 

 

contact the furnace manufacturer or local HVAC service

 

 

 

person for assistance.

 

3.

Heating system requires service or

Diagnostic: Set SYSTEM Switch to HEAT and raise the

 

 

thermostat requires replacement.

setpoint above room temperature. Within a few seconds

 

 

 

the thermostat should make a soft click sound. This sound

 

 

 

usually indicates the thermostat is operating properly. If

 

 

 

the thermostat does not click, try the reset operation listed

 

 

 

above. If the thermostat does not click after being reset

 

 

 

contact your heating and cooling service person or place

 

 

 

of purchase for a replacement. If the thermostat clicks,

 

 

 

contact the furnace manufacturer or a HVAC service

 

 

 

person to verify the heating is operating correctly.

 

 

 

 

No Cool

1.

Cooling system requires service or

Same as diagnostic for No Heat condition except set the

 

 

thermostat requires replacement.

thermostat to COOL and lower the setpoint below the room

 

 

 

temperature. There may be up to a five minute delay before

 

 

 

the thermostat clicks in Cooling.

 

 

 

 

 

1.

Possible short in wiring.

Check each wire connection to verify they are not shorted

Heat, Cool or Fan

2.

Possible short in thermostat.

or touching together. No bare wire should stick out from

Runs Constantly

3.

Possible short in heat/cool/fan system.

under terminal block. Try resetting the thermostat as

 

4.

FAN Switch set to Fan ON.

described above. If the condition persists the manufacturer

 

 

 

of your system or service person can instruct you on how

 

 

 

to test the Heat/Cool system for correct operation. If the

 

 

 

system operates correctly, replace the thermostat.

 

 

 

 

Thermostat Setting &

1.

Thermostat thermometer setting

The thermometer can be adjusted +/- 4 degrees. See

Thermostat Thermometer

 

requires adjustment.

Temperature Display Adjustment in the Configuration Menu

Disagree

 

 

section.

 

 

 

 

Furnace (Air Conditioner)

1.

The location of the thermostat and/or

Digital thermostats provide precise control and cycle faster

Cycles Too Fast or Too

 

the size of the Heating System may

than older mechanical models. The system turns on and off

Slow (narrow or wide

 

be influencing the cycle rate.

more frequently but runs for a shorter time so there is no

temperature swing)

 

 

increase in energy use. If you would like an increased cycle

 

 

 

time, choose SL for slow cycle in the Configuration menu,

 

 

 

step 6 (heat), 7 (cool) or 8 (heat pump). If an acceptable

 

 

 

cycle rate is not achieved, contact a local HVAC service

 

 

 

person for additional suggestions.

 

 

 

 

Forgot Keypad Lockout

 

 

Hold MENU key for 20 seconds and the lockout will reset.

Code

 

 

 

 

 

 

 

Thermostat does not have

1.

Earlier version of thermostat.

Refer to Instruction Sheet 37-7136A.

Menu Screen Numbers

 

 

 

 

 

 

 

9

Image 9
Contents 1F85-0422 Save these instructions for future use1F83-0422 1F83-0422 ThermostatWiring Connections InstallationInstalling New Thermostat Remove Old ThermostatProgramming and Configuration Items Thermostat Quick ReferenceHome Screen Description INSTALLER/CONFIGURATION Menu Press1F85 1F83 Or key Select Temperature Display Adjustment 4 LO to 4 HIChoose the System Setting Heat, Off, Cool, Auto, Emer Choose the Fan Setting Auto or OnManual Operation for Non-Programmable Mode Operating Your ThermostatSet Current Time and Date Second Stage Time DelayEnter the Heating Program Energy Saving Factory Pre-ProgramProgramming TroubleshootingPlanning Your Program Important Worksheet for Re-Programming 5+2 Day and 5+1+1 Day ProgramReset Operation Symptom Possible Cause Correction ActionPage Page Homeowner Help Line
Related manuals
Manual 4 pages 10.06 Kb

1F83-0422 Thermostat, 1F85-0422 specifications

The White Rodgers 1F85-0422 is a highly regarded thermostat known for its innovative features and user-friendly design, making it a popular choice among homeowners and HVAC professionals alike. This programmable thermostat is designed to enhance energy efficiency and comfort in residential settings, allowing users to maintain optimal temperature settings with ease.

One of the standout features of the 1F85-0422 is its programmable functionality, which allows users to set specific heating and cooling schedules for different times of the day and week. This capability helps in reducing energy consumption, as the thermostat can adjust the temperature when the home is unoccupied or during the night when lower temperatures are preferred. With four programmable periods per day, users can easily customize their comfort levels according to their daily routines.

The 1F85-0422 also incorporates advanced technology, including a large, easy-to-read display that clearly shows the current temperature and settings. The backlit LCD screen ensures visibility even in dim lighting, providing convenience for nighttime adjustments. This thermostat features intuitive controls that allow users to navigate through the settings quickly, promoting a straightforward user experience.

Another key characteristic of the White Rodgers 1F85-0422 is its compatibility with various heating and cooling systems. It is designed to work efficiently with gas, electric, and heat pump systems, making it a versatile choice for a wide range of home HVAC configurations. The thermostat also supports multi-stage heating and cooling, ensuring precise temperature control and comfort throughout the home.

Energy-saving features are at the forefront of the 1F85-0422’s design. The thermostat is equipped with an energy-saving mode that optimizes heating and cooling cycles based on the user's preferences and occupancy patterns. Additionally, it provides alerts for regular maintenance, such as filter changes, to ensure that the HVAC system operates at peak efficiency.

In summary, the White Rodgers 1F85-0422 is a programmable thermostat that excels in performance, versatility, and user convenience. Its advanced features, including easy programming, compatibility with various HVAC systems, and energy-saving technologies, make it a reliable choice for enhancing home comfort while minimizing energy costs. Whether you are looking to upgrade your current thermostat or improve your home's energy efficiency, the 1F85-0422 is an excellent option to consider.