Desa Tech CGP10 installation manual Installing Two Mounting Screws, Folding Anchor

Page 11

INSTALLING TO WALL

Continued

Installing Two Mounting Screws

Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater.

Attaching to wall stud method

For attaching mounting screw to wall stud

1.Drill hole at marked location using 9/64" drill bit.

2.Insert mounting screw into wall stud.

3.Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall.

Attaching to wall anchor method

Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry).

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep.

2.Fold wall anchor (see Figure 6).

Figure 6 - Folding Anchor

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 7). IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Thin Walls

(1/4" to 1/2" thick)

Figure 7 - Popping Open Anchor Wings For Thin Walls

5.Tighten two screws until 1/16" space (thickness of penny) is between screwheads and wall (see Figure 8).

Thin or Thick Wall

(thick wall shown)

1/16" Space

Solid Wall

ANCHOR

Figure 8 - Tightening Anchors

099403

11

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationProducing Adequate Ventilation Fresh AIR ForCombustion VentilationDetermining if You Have a Confined or Unconfined Space Fresh AIRDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Fresh AIR for Combustion and VentilationVentilation AIR Ventilation Air From Outdoors Ventilation AIRLocating Heater Installing To WallInstallation Items Check GAS TypeMarking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Follow all local codes Connecting To GASQualified service person must connect heater to gas supply SupplyConnections Pressure Testing GAS Supply Piping SystemChecking GAS Checking GAS Connections Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingOperating HeaterShutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterCorrect Burner Flame Pattern Burner Flame PatternODS/PILOT and Burner Orifice CleaningMaintenance Trouble ShootingTrouble Cleaning and MainteLOW TROUBLE- ShootingIng statement at If you smell gasShut off gas supply Do not try to light any applianceParts ServiceTechnical HintsValve GA5010 Service Publications AccessoryParts Centrals CGP10 Parts List CGP10 Keep this Warranty Warranty Information