TROUBLE- | WARNING | |
SHOOTING | If you smell gas | |
Continued | • Shut off gas supply. | |
• Do not try to light any appliance. | ||
|
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED | POSSIBLE |
|
|
|
| |||
PROBLEM | CAUSE |
| REMEDY |
| ||||
|
|
|
|
|
|
|
| |
Heater produces a | 1. | Metal expanding while | 1. | This is common with |
| |||
clicking/ticking noise |
| heating or contracting |
| most heaters. If noise is |
| |||
just after burner is lit or |
| while cooling |
| excessive, contact quali- |
| |||
shut off |
|
|
|
| fied service person |
| ||
|
|
|
|
|
|
|
| |
Heater produces un- | 1. | Heater burning vapors | 1. | Ventilate room. Stop us- |
| |||
wanted odors |
| from paint, hair spray, |
| ing |
| |||
|
|
|
| glues, etc. (See IMPOR- |
| ucts while heater is run- |
| |
|
|
|
| TANT statement above) |
| ning |
| |
|
|
| 2. | Low fuel supply | 2. | Refill supply tank |
| |
|
|
| 3. | Gas leak. See Warn- | 3. | Locate and correct all |
| |
|
|
|
| ing statement at |
| leaks (see Checking Gas |
| |
|
|
|
| top of page |
| Connections, page 14) |
| |
|
|
|
|
|
|
|
| |
Heater shuts off in use | 1. | Not enough fresh air is | 1. | Open window and/or |
| |||
(ODS operates) |
| available |
|
| door for ventilation |
| ||
|
|
| 2. | Low line pressure | 2. | Contact local propane |
| |
|
|
|
|
|
|
| gas company |
|
|
|
| 3. | ODS/pilot | is partially | 3. | Clean ODS/pilot (see |
|
|
|
|
| clogged |
|
| Cleaning and Mainte- |
|
|
|
|
|
|
|
| nance, page 20) |
|
|
|
|
|
|
|
| ||
Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct all |
| |||
control knob is in OFF |
| ing statement at |
| |||||
|
| leaks (see Checking Gas |
| |||||
position |
| top of page |
|
| ||||
|
| Connections, page 14) |
| |||||
|
|
| 2. | Control valve defective |
|
| ||
|
|
| 2. | Replace control valve |
| |||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
Gas odor during com- | 1. | Foreign matter between | 1. | Take apart gas tubing |
| |||
bustion |
| control | valve and |
| ||||
|
| and remove foreign mat- |
| |||||
|
|
|
| burner |
|
|
| |
|
|
|
|
|
| ter |
| |
|
|
| 2. | Gas leak. See Warn- |
|
| ||
|
|
| 2. | Locate and correct all |
| |||
|
|
|
|
|
|
|
ing statement at | leaks (see Checking Gas | ||
top of page | |||
Connections, page 14) | |||
| |||
|
|
| |
| 23 |
099403