Desa Tech CGP10 installation manual Operating Heater, For Your Safety Read Before Lighting

Page 16

16

OPERATING HEATER

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise

Clockwise to the OFF position.

 

Ignitor Button

Control Knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PILOT

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

IGNITOR

LOW

Figure 16 - Control Knob In The OFF Position

099403

Image 16
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Local Codes Unpacking Product Features Safety DeviceProduct Identification Piezo Ignition SystemFresh AIR For CombustionVentilation Producing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Fresh AIRDetermining if You Have a Confined or Unconfined Space Ventilation AIR Fresh AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation AIR Ventilation Air From OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting To GAS Qualified service person must connect heater to gas supplySupply Follow all local codesChecking GAS Pressure Testing GAS Supply Piping SystemConnections Pressure Testing Heater GAS Connections Checking GAS ConnectionsFor Your Safety Read Before Lighting Operating HeaterHeater OperatingOperating Heater Inspecting Burner Pilot Flame PatternShutting Off Heater Shutting Off Burner Only pilot stays litBurner Flame Pattern Correct Burner Flame PatternCleaning MaintenanceTrouble Shooting ODS/PILOT and Burner OrificeCleaning and Mainte TroubleTROUBLE- Shooting LOWIf you smell gas Shut off gas supplyDo not try to light any appliance Ing statement atService TechnicalHints PartsParts Centrals Service Publications AccessoryValve GA5010 CGP10 Parts List CGP10 Warranty Information Keep this Warranty