Desa FG30PT, GG30NT, FG30NT Inspecting Heater, Pilot Flame Pattern, Burner Flame Pattern

Page 18

INSPECTING HEATER

Check pilot flame pattern and burner flame pat- tern often.

PILOT FLAME PATTERN

Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 24

turn heater off (see To Turn Off Gas to Appli- ance, page 16 or 17)

see Troubleshooting, page 20

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Thermocouple

Blue Flame

Pilot Burner

Figure 23 - Correct Pilot Flame Pattern

Thermocouple

Yellow Flame

Pilot

Burner

Figure 24 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

Figure 25 shows a correct burner flame pattern. Figure 26 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the heat shield height.

If burner flame pattern is incorrect, as shown in Figure 26

turn heater off (see To Turn Off Gas To Appli- ance, page 16 or 17)

see Troubleshooting, page 20

 

Blue

 

Flame

 

/2

Heat

1

Shield

 

 

Height

Figure 25 - Correct Burner Flame Pattern

 

 

Yellow

 

 

Tipping

 

/2

Heat

1

Shield

 

 

Height

Figure 26 - Incorrect Burner Flame

Pattern

 

 

18

www.desatech.com

114683-01B

Image 18
Contents What to do if YOU Smell GAS Table of Contents Safety Information Poisoning may lead to deathProduct Features Local CodesUnpacking Following are excerpts from National Fuel AIR for Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceCheck GAS Type InstallationVentilation AIR Ventilation Air From Inside BuildingInstallation Items Locating HeaterMounting Bracket Installing Heater to WallThermostat Sensing Bulb Thermostat Models Only Removing Front Panel Of HeaterAttaching To Wall Anchor Method Placing Heater On Mounting BracketInstalling Bottom Mounting Screws Installing Bottom Mounting ScrewsConnecting to GAS Supply Typical Inlet Pipe DiameterPsig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than EquipmentOpen equipment shutoff valve see , Make sure control knob of heater is in the OFF positionManual Control Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions Shutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burner Only pilot stays litThermostat Control Operation Burner Flame Pattern Inspecting HeaterPilot Flame Pattern Check pilot flame pattern and burner flame pat- tern oftenBurner Pilot AIR Inlet Cleaning MaintenanceODS/PILOT and Burner CabinetTroubleshooting Observed Problem Possible Cause RemedyDelayed ignition of burner Manifold pressure is too low Out when control knob is re Control knob not pressedSafety interlock system has Burner orifice is clogged Clean burner see CleaningTurning control knob to Or shut off Qualified service personOperation Processes Hours of operation Air passageways on heaterGas leak. See Warning Statement aboveSpecifications BG30N, FG30N, GG30N, RG30N, GMG30NBG30P, FG30P, GG30P, RG30P, GMG30P Service Publications Replacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List NJF 8CIllustrated Parts Breakdown NJF 8C FAN Kits GA3250T AccessoriesEquipment Shutoff Valve GA5010 For all models. Equipment shutoff valve with 1/8 NPT tapParts Centrals Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Residential GAS Heaters