Desa CGP20L, RP30D installation manual Safety Information, Local Codes, Unpacking, Product Features

Page 2

BLUE-FLAME CGP20, CGP20L AND RP30D

VENT-FREE PROPANE/LP GAS HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, elec- trical shock, and carbon monox- ide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, per- sons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to propane/LP gas. The odor helps you detect a propane/LP gas leak. However, the odor added to propane/LP gas can fade. Propane/ LP gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dan- gerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.This heater shall not be installed in a bedroom or bathroom.

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

5.Never install the heater

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

6.This heater needs fresh, outside air ven- tilation to run properly. This heater has an oxygen depletion sensor (ODS) pi- lot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 3 through 5.

7.Keep all air openings in the front and bottom of heater clear and free of de- bris. This will insure enough air for proper combustion.

8.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

9.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

10.Never place any objects on the heater.

11.Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns and clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

12.Make sure grill guard is in place be- fore running heater.

13.Carefully supervise young children when they are in same room with heater.

14.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

15.Turn off heater and let cool before ser- vicing. Only a qualified service person should service and repair heater.

16.Operating heater above elevations of 4,500 feet could cause pilot outage.

17.To prevent performance problems, do not use propane fuel tank of less than than 100 lbs. capacity.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging ap- plied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

PRODUCT

FEATURES

Safety Device

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Piezo Ignition System

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

2

103569

Image 2
Contents CGP20 RP30DWhat to do if YOU Smell GAS CGP20LLocal Codes Safety InformationProduct Features UnpackingProviding Adequate Ventilation Product IdentificationAIR for Combustion and Ventilation Unusually Tight ConstructionVentilation Air From Inside Building Determining AIR Flow for Heater LocationVentilation AIR AIR for Combustion Ventilation Ventilation Air From OutdoorsCheck GAS Type Installing to WallInstallation Items Locating HeaterInstalling Heater to Wall Placing Heater On Mounting Bracket Connecting to GAS SupplyInstalling Bottom Mounting Screws Checking GAS Connections Pressure Testing GAS Supply Piping SystemPressure Testing Heater GAS Connections PsigLighting Instructions For Your Safety Read Before LightingOperating Heater Pilot Flame Pattern Manual Lighting ProcedureInspecting Burner Burner Flame PatternTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Specifications Cleaning and MaintenanceTechnical Service Service HintsParts Not Under Warranty Replacement PartsParts Under Warranty Parts CentralsFAN Kits GA3100A AccessoriesManual Shutoffvalve Floor Mounting StandIllustrated Parts Breakdown Parts List KEY Part Number Description QTYCGP20 CGP20L Parts List 103569 103569 Warranty Information Limited Warranty Comfort Glow VENT-FREE Heaters

RP30D, CGP20, CGP20L specifications

Desa CGP20L, CGP20, and RP30D are advanced generators designed for maximum efficiency, reliability, and versatility. These units cater to a wide range of applications, making them a solid choice for both residential and commercial use.

The Desa CGP20L is a portable generator that delivers reliable power in a compact design. With a robust 20,000 watts capacity, it ensures that users can run multiple appliances simultaneously without compromising performance. It features a powerful engine that provides consistent power output, making it ideal for outdoor events, construction sites, or as backup power during outages. The CGP20L is equipped with an easy-to-read digital display that provides critical information about power usage and operating status.

In terms of fuel efficiency, the CGP20L incorporates a technology that minimizes fuel consumption while maximizing output. This feature not only reduces running costs but also lowers emissions, making it an environmentally friendly option. The generator also comes with multiple outlets, ensuring compatibility with a vast array of devices, further enhancing its versatility.

The CGP20 model is another notable offering from Desa, featuring a slightly lower capacity at 18,000 watts. It combines portability with power, designed to be lightweight yet durable. The generator boasts a quiet operation, thanks to advanced sound-dampening technologies. It is particularly well-suited for residential use, including during home improvement projects, recreational activities, or emergency situations. The CGP20 also prioritizes user safety, featuring circuit protection mechanisms to prevent overloads.

On the other hand, the RP30D is designed for heavy-duty use, offering an impressive 30,000-watt capacity. This model is ideal for industrial applications, construction sites, and large events where a significant power supply is necessary. The RP30D incorporates advanced control systems that enhance performance and operational efficiency. It is also designed with rugged features, ensuring resilience in harsh conditions.

All models are designed with user-friendly controls, ensuring ease of operation irrespective of technical expertise. They also prioritize serviceability, facilitating quick maintenance and reducing downtime. With durability, efficiency, and advanced technology at their core, the Desa CGP20L, CGP20, and RP30D generators stand out as reliable solutions for diverse power needs. Whether for personal, commercial, or industrial use, these generators deliver performance you can trust.