Desa RP30D, CGP20L installation manual Installing Heater to Wall

Page 7

OWNER’S MANUAL

INSTALLING TO WALL

Continued

INSTALLING HEATER TO WALL

Mounting Bracket

The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.

Mounting

Bracket

Figure 5 - Mounting Bracket Location

Removing Front Panel Of Heater

1.Remove two screws near bottom cor- ners of front panel.

2.Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".

3.Pull bottom of front panel forward, then down.

4.Remove cardboard packing from grill and glass (CGP20[L]) or heat shield (RP30D).

Figure 6 - Removing Front Panel Of Heater

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching to wall stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to wall anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

2.Mark screw locations on wall (see Fig- ure 7).

WARNING: Maintain minimum clearances shown in Figure 7. If you can, provide greater clear- ances from floor and joining wall.

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

11"

16"

Min.

 

AdjoiningWall

 

Only Insert Mounting

 

32 1/2"

 

 

Screws Through Last

 

 

Min.

 

 

Hole On Each End

 

 

 

 

 

 

 

Floor

 

 

 

 

RP30D

 

 

 

7 1/4"

16"

 

 

 

Min.

 

 

 

AdjoiningWall

Only Insert Mounting

18 3/4"

Screws Through Last

 

Min.

 

 

Hole On Each End

 

 

 

 

 

Floor

CGP20(L)

Figure 7 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 8.

Figure 8 - Folding Anchor

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings.

MPORTANT: Do not hammer key!

For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Figure 9 - Popping Open Anchor Wings For Thin Walls

5.Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Continued

103569

7

Image 7
Contents CGP20L RP30DWhat to do if YOU Smell GAS CGP20Unpacking Safety InformationProduct Features Local CodesUnusually Tight Construction Product IdentificationAIR for Combustion and Ventilation Providing Adequate VentilationVentilation AIR Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation Air From Outdoors AIR for Combustion VentilationLocating Heater Installing to WallInstallation Items Check GAS TypeInstalling Heater to Wall Installing Bottom Mounting Screws Connecting to GAS SupplyPlacing Heater On Mounting Bracket Psig Pressure Testing GAS Supply Piping SystemPressure Testing Heater GAS Connections Checking GAS ConnectionsOperating Heater For Your Safety Read Before LightingLighting Instructions Burner Flame Pattern Manual Lighting ProcedureInspecting Burner Pilot Flame PatternObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Service Hints Cleaning and MaintenanceTechnical Service SpecificationsParts Centrals Replacement PartsParts Under Warranty Parts Not Under WarrantyFloor Mounting Stand AccessoriesManual Shutoffvalve FAN Kits GA3100AIllustrated Parts Breakdown KEY Part Number Description QTY Parts ListCGP20 CGP20L Parts List 103569 103569 Limited Warranty Comfort Glow VENT-FREE Heaters Warranty Information

RP30D, CGP20, CGP20L specifications

Desa CGP20L, CGP20, and RP30D are advanced generators designed for maximum efficiency, reliability, and versatility. These units cater to a wide range of applications, making them a solid choice for both residential and commercial use.

The Desa CGP20L is a portable generator that delivers reliable power in a compact design. With a robust 20,000 watts capacity, it ensures that users can run multiple appliances simultaneously without compromising performance. It features a powerful engine that provides consistent power output, making it ideal for outdoor events, construction sites, or as backup power during outages. The CGP20L is equipped with an easy-to-read digital display that provides critical information about power usage and operating status.

In terms of fuel efficiency, the CGP20L incorporates a technology that minimizes fuel consumption while maximizing output. This feature not only reduces running costs but also lowers emissions, making it an environmentally friendly option. The generator also comes with multiple outlets, ensuring compatibility with a vast array of devices, further enhancing its versatility.

The CGP20 model is another notable offering from Desa, featuring a slightly lower capacity at 18,000 watts. It combines portability with power, designed to be lightweight yet durable. The generator boasts a quiet operation, thanks to advanced sound-dampening technologies. It is particularly well-suited for residential use, including during home improvement projects, recreational activities, or emergency situations. The CGP20 also prioritizes user safety, featuring circuit protection mechanisms to prevent overloads.

On the other hand, the RP30D is designed for heavy-duty use, offering an impressive 30,000-watt capacity. This model is ideal for industrial applications, construction sites, and large events where a significant power supply is necessary. The RP30D incorporates advanced control systems that enhance performance and operational efficiency. It is also designed with rugged features, ensuring resilience in harsh conditions.

All models are designed with user-friendly controls, ensuring ease of operation irrespective of technical expertise. They also prioritize serviceability, facilitating quick maintenance and reducing downtime. With durability, efficiency, and advanced technology at their core, the Desa CGP20L, CGP20, and RP30D generators stand out as reliable solutions for diverse power needs. Whether for personal, commercial, or industrial use, these generators deliver performance you can trust.