Desa DH2304 owner manual ¢ Long Term Storage of Your Heater

Page 14

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

TESTING THE SAFETY SHUT-OFF DEVICE : At least once a week during the heating season, it is important to test the safety shut-off device to be sure that it is operating properly. WITH THE HEATER TURNED OFF, raise the wick using the wick adjuster knob to the fully raised position. Grabbing the protective grille, give the heater a firm shake. If the safety shut-off device is working properly, you will hear a loud noise as the ratchet is disengaged and the torsion spring drops the wick into the body of the heater. To verify that the wick has been completely lowered, turn the wick adjuster knob in a counterclockwise direction. If the safety shut-off device is functioning properly, the wick will have been completely lowered. If you are able to lower the wick further using the wick adjuster knob, this means that it is time to perform the "Carbon Removal Dry Burning" procedure described on page 8 again.

¢￿ LONG TERM STORAGE OF YOUR HEATER

Carefully following the instructions for storage given below will insure that your heater will operate efficiently and safely next season (Fig. 19/ Fig. 20).

¡'Using a small amount of kerosene, swirl and rinse the inside of the tank. NEVER mix water with the kerosene as it will cause rust inside the tank. Pour the kerosene out making sure that you remove it all.

¡'With the fuel tank empty, ignite the heater. With the wick at its maximum height, keep the wick burning until it burns out completely (about 1 hour). It is a good idea to do this outside or in an extremely well- ventilated area.

¡'Remove the batteries. Remove the 2 cabinet screws and lift off the the cabinet and grille assembly. Remove the burner. Remove the wick adjuster from the fuel reservoir. Throughly dry the inside of the fuel tank. Using a screwdriver and/or a brush, remove any carbon, tar or soot that might have accumulated on the wick adjuster, wick guide or burner.

¡'After a thorough cleaning, reassemble the heater. It is important when reassembling the wick adjuster to be sure to maintain an equal gap between the wick adjuster and the wick guide cylnder all around. See "Wick Replacement" on page7 for reference.

¡'Remove the batteries from the battery case before storing the heater to prevent leakage and corrosion.

¡'Store the heater with the wick in the fully lowered position and the safety shut-off device deactivated.

¡'Store the heater in the original box with the original packing material and keep the OWNER'S MANUAL with the heater. Store in an area that is well- ventilated.

Owner’s

Manual

Siphon

Pump

Fig.19

Fig.20

13

Image 14
Contents DuraHeat Save These Instructions for Future Reference ¢ Introduction ¢FEATURES ¢ Extinguishing the Heater¢Ł Unpacking and Assembly Installing Front and Rear GUARDSFig¢Ø Kerosene 1-K only ¢Œ Fueling Your Heater This HeaterTo use the automatic ignition system Procedure is as followsIgnition VIA Match Perform the following checks ¢ Adjusting the Wick¢ Checking the Ignition System To replace the igniter plug Fig¢ Wick Maintenance / HOW to Check the Condition of Your Wick ¢ DRY Burning Your Heater / Removing Carbon from Your Wick¢ Wick ASSEMBLY- Check at least once a month Wick Cover firmly Never Leave the Heater Unattended While Burning ¢ Automatic Safety SHUT-OFF Device ¢ Extinguishing the Heater¢ Long Term Storage of Your Heater Fill tank with water-clear 1-K kerosene Wick Adjuster SticksHeater Will Not Light KeroseneParts List ¢ Exploded Parts Drawing