NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
¢ CHECKING THE IGNITION SYSTEM
If the automatic ignition system fails to operate properly,
perform the following checks:
¡'BATTERIES | Igniter | |
Replace with new batteries. |
| |
Fig.15 | ||
¡'IGNITER PLUG - If the automatic ignition system still doesn't work | ||
after replacing the batteries, check the igniter plug. If the glow coil |
|
filament is broken, bent, or doesn't glow when engaged via the ignition lever, it must be replaced.
CAUTION: Be sure igniter plug is Type "B", 2.5V DC, 1A only.
To replace the igniter plug (Fig. 15);
¡'Remove the batteries.
¡'Remove the 2 cabinet screws and lift off the cabinet and grille assembly. ¡'Pull the ignition lever to raise the igniter plug.
¡'Push the igniter plug in and turn in a clockwise direction to remove.
¡'Install a new igniter plug (Type "B", 2.5V DC, 1A only) by pushing it in and turning it in a
¡'Reassemble the heater and replace the batteries.
¡'TEST IGNITION ¡'Using the wick adjuster knob, raise the wick to its maximum height.
Pull the ignition lever.
The igniter plug should be within 1~2mm of the wick when the ignition lever is fully engaged.
¢ ADJUSTING THE WICK
After lighting the heater, it is important to check the heater flame within the first
As you continue to operate the heater, the temperature of the heater and the temperature of the room will continue to change. As the heater warms up, the kerosene in the tank will vaporize faster, and this could require adjusting the wick adjuster down in order to maintain the desired 1/2" flame height. Therefore, it is necessary to continue to monitor the flame height, and to make adjustments using the wick adjuster knob to keep the proper flame height. It is recommended that the heater be checked every 30 minutes in order to keep the proper adjustment because periodic adjustment is required.
Fig.16
CORRECT FLAME | FLAME TOO HIGH | FLAME TOO LOW |
Proper combustion | Can Produce smoke | Can produce odor |
| and soot | and carbon monoxide |
IMPORTANT NOTE : NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING.
Always make sure to turn the heater off and inspect it to insure that it is completely extinguished prior to going to bed.
7