Desa DH2304 owner manual Heater Will Not Light, Fill tank with water-clear 1-K kerosene, Kerosene

Page 15

 

 

 

 

 

NEVER LEAVE THE HEATER

 

 

 

 

 

UNATTENDED WHILE BURNING!

¢ı TROUBLE SHOOTING GUIDE

 

 

 

 

 

 

 

 

 

TROUBLE

CORRECTIVE ACTION

 

 

 

 

 

Heater Will Not Light ;

 

 

1.

Fuel tank is empty

1. Fill tank with water-clear 1-K kerosene.

2.

Water present in kerosene

2. Drain tank. Remove wick assembly & replace wick.

 

 

 

 

Reinstall wick assembly. Fill tank with water-clear

 

 

 

 

1-K kerosene.

3.

Igniter plug fails to glow

3. Replace batteries. Replace igniter plug. Check for broken or

 

 

 

 

disconnected wire.

4.

Igniter plug makes contact with

4. Lower wick using wick adjuster knob until igniter plug makes

 

 

side of wick

contact with top of wick.

 

Heater Produces Smoke or Odor ;

 

 

1.

Flame is too high

1. Using wick adjuster knob, lower wick to desired 1/2” flame.

2.

Heater is in an air draft

2. Move heater out of air draft.

3.

Burner is not level

3. Using burner knob, rotate burner from side to side until it seats

 

 

 

 

properly over wick.

4.

Carbon or tar built up on wick

4. Perform "Carbon Removal / Dry Burning" procedure.

 

 

 

 

Replace wick if necessary.

5.

Contaminated kerosene

5. Drain tank. Remove wick assembly & replace wick.

 

 

 

 

Reinstall wick assembly. Fill tank with water-clear

 

 

 

 

1-K kerosene.

 

Flame Flickers or Dies ;

 

 

1.

Water present in kerosene

1. Drain tank. Remove wick assembly & replace wick.

Reinstall wick assembly. Fill tank with water-clear

 

 

 

 

 

 

 

 

1-K kerosene.

2.

Carbon or tar built up on wick

2. Perform "Carbon Removal / Dry Burning" procedure.

Replace wick if necessary.

 

 

 

 

 

 

 

 

 

Wick Burning Down Excessively ;

 

 

1.

Dangerous, volatile fuel mixed with

1. Drain and clean tank

 

 

kerosene (gasoline, benzene, alcohol,

¡'Remove and replace wick

 

 

white gas, paint thinner, camp, stove

¡'Fill tank with water-clear 1-K kerosene.

 

 

fuel, oil compound)

 

 

 

 

 

 

 

Wick Adjuster Sticks ;

 

 

 

1. Water present in kerosene

1. Drain tank. Remove wick assembly & replace wick.

 

 

 

 

Reinstall wick assembly. Fill tank with water-clear

 

2. Carbon or tar built up

1-K kerosene.

 

2. Perform "Carbon Removal / Dry Burning" procedure.

 

 

 

 

Replace wick if necessary.

 

 

 

 

Wick will not raise ;

¡'Push the safety reset lever (see diagram on P.2) to engage

 

 

 

 

the automatic safety shut-off device.

 

 

 

 

Then dial the wick up via the wick adjuster knob.

 

 

 

 

Heater is enveloped in flames ;

¡'Call Fire Department.

 

 

 

 

¡'Smother flames with fire extinguisher or sand. Otherwise

 

 

 

 

smother flames with blankets and then throw water on

 

 

 

 

blankets. Do not throw water directly on the heater itself.

 

 

 

 

 

 

14

Image 15
Contents DuraHeat Save These Instructions for Future Reference ¢ Extinguishing the Heater ¢ Introduction ¢FEATURESInstalling Front and Rear GUARDSFig ¢Ł Unpacking and Assembly¢Ø Kerosene 1-K only This Heater ¢Œ Fueling Your HeaterProcedure is as follows Ignition VIA MatchTo use the automatic ignition system To replace the igniter plug Fig ¢ Adjusting the Wick¢ Checking the Ignition System Perform the following checks¢ DRY Burning Your Heater / Removing Carbon from Your Wick ¢ Wick Maintenance / HOW to Check the Condition of Your Wick¢ Wick ASSEMBLY- Check at least once a month Wick Cover firmly Never Leave the Heater Unattended While Burning ¢ Extinguishing the Heater ¢ Automatic Safety SHUT-OFF Device¢ Long Term Storage of Your Heater Kerosene Wick Adjuster SticksHeater Will Not Light Fill tank with water-clear 1-K kerosene¢ Exploded Parts Drawing Parts List