Desa GP30 GN30T Cleaning Maintenance, Burner Flame Pattern, Cleaning Burner Pilot AIR Inlet

Page 16

16

INSPECTING HEATER

Burner Flame Pattern

CLEANING AND MAINTENANCE

ODS/Pilot and Burner

Cleaning Burner Pilot Air Inlet

Cabinet

INSPECTING HEATER

Continued

BURNER FLAME PATTERN

ODS/PILOT AND BURNER

WARNING: If yellow tipping occurs, your heater could produce increased levels of carbon monoxide.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

Figure 25 shows a correct burner flame pattern. Figure 26 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

If burner flame pattern is incorrect, as shown in Figure 26

turn heater off (see To Turn Off Gas To Appliance, page 14 or 15)

see Troubleshooting, pages 17 through 19

Blue

Flame

1/2 Glass

Height

Figure 25 - Correct Burner Flame Pattern

Yellow Tipping

1/2 Glass

Height

Figure 26 - Incorrect Burner Flame Pattern

CLEANING AND

MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CLEANING BURNER PILOT AIR INLET

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot for dust and dirt.

3.Blow air through the ports/slots and holes in the burner.

4.Never insert objects into the pilot tube.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet about two inches from where the pilot flame comes out of the pilot assembly (see Figure 27). With the unit off, lightly blow air through the air inlet. You may blow through a drinking straw if compressed air is not available.

Pilot Assembly

Pilot Air Inlet

Figure 27 - Pilot Inlet Air (Propane/LP Pilot Shown)

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

For..com

107884

Image 16
Contents GWN20T, GWP20T GWN30T, GWP30T What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Product Identification Product FeaturesLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Attaching Thermostat Sensing BulbMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting Screws Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor with Optional Floor KIT Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Heater Manual Control Models For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure To Turn OFF GAS to ApplianceShutting Off Heater Shutting Off Burner Only pilot stays litPilot Flame Pattern Inspecting HeaterThermostat Control Operation Cleaning Maintenance Cleaning Burner Pilot AIR InletBurner Flame Pattern CabinetTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Illustrated Parts Breakdown Parts List WMN20 WMP20 Description QTYGWN30T, GWP30T GGN30T, GP30T GWN20T, GWP20T, GWN30T, GWP30T Specifications Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required Accessories Parts CentralsEquipment Shutoff Valve GA5010 FAN Kits GA3250TWarranty Information