Desa GP30 GN30T, WMP20, GWP20 GWN20T Marking Screw Locations, Attaching Mounting Bracket To Wall

Page 9

INSTALLATION

Installing Heater To Wall (Cont.)

9

INSTALLATION

Continued

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

WARNING: Maintain minimum clearances shown in Figure 8. If you can, provide greater clearances from floor and joining wall.

2.Mark screw locations on wall (see Figure 8).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

12"

14"

Min.

 

AdjoiningWall

Only Insert Mounting

18 3/4"

 

Screws Through Last

Min.

 

Hole On Each End

 

 

 

Floor

 

30,000 Btu/Hr Models

8"

14"

 

Min.

 

AdjoiningWall

Only Insert Mounting 18 3/4"

Screws Through Last

Min.

 

Hole On Each End

 

 

Floor

20,000 Btu/Hr Models

Figure 8 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs

1. Drill holes at marked locations using 9/64" drill bit.

2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching To Wall Anchor Method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 9.

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings.

IMPORTANT: Do not hammer key!

For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

5.Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Placing Heater On Mounting Bracket

1.Locate two horizontal slots on back panel of heater.

2.Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Figure 9 - Folding Anchor

Figure 10 - Popping Open

 

Anchor Wings For Thin Walls

Horizontal Slots

Stand-Out Tab

 

Mounting Bracket

 

 

(attached to wall)

 

 

 

 

 

Figure 11 - Mounting Heater Onto Mounting Bracket

For more information, visit www.desatech.com

107884

Image 9
Contents What to do if YOU Smell GAS GWN20T, GWP20T GWN30T, GWP30TSafety Information Table of ContentsProduct Features Safety Information Product IdentificationLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterAttaching Thermostat Sensing Bulb Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterMarking Screw Locations Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Mounting Base Feet to Floor Where required by local code Installing Bottom Mounting ScrewsMounting Heater to Floor with Optional Floor KIT Mounting Base Feet to HeaterTypical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Manual Control Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burner Only pilot stays litInspecting Heater Pilot Flame PatternThermostat Control Operation Cleaning Burner Pilot AIR Inlet Cleaning MaintenanceBurner Flame Pattern CabinetObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Illustrated Parts Breakdown WMN20 WMP20 Description QTY Parts ListGWN30T, GWP30T GGN30T, GP30T GWN20T, GWP20T, GWN30T, GWP30T Replacement Parts SpecificationsService Hints Technical ServiceOwners Registration Form Postage Required Parts Centrals AccessoriesEquipment Shutoff Valve GA5010 FAN Kits GA3250TWarranty Information