Desa RCLP155B Propane Supply, Installation, Temperature ˚C F Number At Tank Location Tanks

Page 4

CANADIAN RCLP155B

PROPANE CONSTRUCTION HEATER

PROPANE

SUPPLY

Propane gas and propane tank(s) are to be furnished by the user.

Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58

INSTALLATION

WARNING: Review and un- derstand the warnings in the Safety Information section, page

2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

6.Close propane supply valve.

and/or CAN/CGA B149.2. Your local library or fire department will have this booklet.

The amount of propane gas ready for use from propane tanks varies. Two factors de- cide this amount:

WARNING: Test all gas piping and connections for leaks after installing or servicing. Never use an open flame to check for a leak.

Regulator

Supply

Valve

Hose

1.The amount of propane gas in tank(s)

2.The temperature of tank(s)

The chart below shows the number of 45 kg (100 lb) tanks needed to run this heater.

Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Propane

Vent

Tank

(pointing

 

 

over hose)

 

POL Fitting

Do not operate this product with any tank smaller than 45 kg (100 lb).

Temperature ˚C (°F)

Number of

At Tank Location

tanks

0 (32)

2

6.7 (20)

2

-12 (10)

3

-18 (0)

3

-23 (-10)

(Use larger

-29 (-20)

tank)

Less gas is vaporized at lower temperatures. You may need two or more 45 kg (100 lb) tanks or one larger tank in colder weather. Your local propane gas dealer will help you select the proper supply system. The mini- mum surrounding-air temperature rating for each heater is -29 °C (-20 °F).

1.Provide propane supply system (see Propane Supply, column 1).

2.Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL fitting counterclockwise into threads on tank. Tighten firmly using wrench. Tighten regulator with vent pointing over the hose (see Figure 3).

3.Connect hose to inlet connector. Tighten firmly using a wrench (see Fig- ure 4).

IMPORTANT: Extra hose or piping may be used if needed. Install extra hose or piping between hose/regulator assembly and propane tank. You must use the regulator supplied with heater .

4.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on pro- pane tank may stop gas flow. If this happens, close propane supply valve and open again slowly.

5.Check all connections for leaks.

Figure 3 - Regulator With Vent Pointing Over Hose

Hose

Inlet Connector

Figure 4 - Hose and Inlet Connector

4

103909

Image 4
Contents Canadian Propane Construction Heater Safety Information Canadian RCLP155B Propane Construction HeaterSafety Control System Product IdentificationUnpacking TheoryTemperature ˚C F Number At Tank Location Tanks InstallationPropane Supply Maintenance Preventative Maintenance ScheduleVentilation StorageService Procedures Upper Shell RemovalFAN IgnitorSpecifications Wiring DiagramsIllustrated PARTS2 Breakdown RCLP155BParts List KEY Part Description QTYTechnical Service AccessoriesReplacement Parts 103909 Warranty and Repair Service Manuel D’UTILISATION Modele RCLP155BInformations Concernant LA Sécurité AvertissementsDéballage Identification DU ProduitPrincipe DE Fonctionnement Alimentation EN PropaneMoyennes C Nombre de BouteillesToute fuite Détendeur avec aérateur dirigé vers le flexibleFonctionnement RemisageEntretien Programme ’ENTRETIEN PréventifVentilateur Procédures ’ENTRETIENAllumeur Caractéristiques Schémas DE CâblageAccessoires Service TechniquePièces Détachées Pièces Sous GarantieVUE Éclatée DES Pièces Liste DES Pièces Pièce RÉF Description QTÉGarantie ET Réparations