Desa RCCP80V owner manual Safety Information

Page 2

2

SAFETY INFORMATION

SAFETY INFORMATION

WARNINGS

WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.

WARNING: FIRE, BURN, INHALATION, AND EX- PLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARD- BOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUC- TIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASO- LINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.

WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE.

The heater is designed for use as a construction heater in accordance with ANSI Z83.7/CGA 2.14. Other standards govern the use of fuel gases and heating products for specific uses. Your local authority can advise you about these. The primary purpose of construction heaters is to provide temporary heating of buildings under construc- tion, alteration or repair. Properly used, the heater provides safe economical heating. Products of combustion are vented into the area being heated.

We cannot foresee every use which may be made of our heaters.

CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT HEATER USE.

Other standards govern the use of fuel gases and heat producing products for specific uses. Your local authorities can advise you about these.

Carbon Monoxide Poisoning: Some people are more affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Check for proper ventilation and have heater serviced.

Propane Gas: Propane gas is odorless. An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas may fade. Propane gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

Install and use heater with care. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and the Propane Installation Code, CAN/CGA B149.2. This instructs on the safe storage and handling of pro- pane gases.

Use only the hose and factory preset regulator provided with the heater.

Use only propane gas set up for vapor withdrawal.

Provide adequate ventilation. Before using heater, provide at least a .23 m2 (2.5 ft2) opening of fresh, outside air.

For indoor use only. Do not use heater outdoors.

Do not use heater in occupied dwellings or in living or sleeping quarters.

Do not use heater in basement or below ground level. Propane gas is heavier than air. If a leak occurs, propane gas may sink to the lowest possible level.

Keep appliance area clear and free from combustible materials, gasoline, paint thinner, and other flammable vapors and liquids. Dust is combustible. Do not use heater in areas with high dust content.

Minimum heater clearances from combustibles: Sides: 9 m (3 ft) Top: 1.8 m (6 ft)

Keep heater at least 1.8 m (6 ft) from propane tank(s).

Keep propane tank(s) below 38° C (100° F).

Check heater for damage before each use. Do not use a dam- aged heater.

Check hose before each use of heater. If highly worn or cut, re- place with hose specified by the manufacturer before using heater.

Locate heater on stable and level surface if heater is hot or operating.

Not intended for use on finished floors.

Never block air inlet (bottom of shell) or air outlet (around top of shell) of heater.

Keep heater away from strong drafts, wind, water spray, rain, or dripping water.

Do not leave heater unattended.

Keep children and animals away from heater.

Never move, handle, or service a hot or operating heater. Severe burns may result. Wait 15 minutes after turning heater off.

To prevent injury, wear gloves when handling heater.

Never attach duct work to heater.

Do not alter heater. Keep heater in its original state.

Do not use heater if altered.

Turn off propane supply to heater when not in use.

Use only original replacement parts. This heater must use de- sign-specific parts. Do not substitute or use generic parts. Im- proper replacement parts could cause serious or fatal injuries.

For morevisit www..com

104781-01D

Image 2
Contents Table of Contents Canadian Propane Construction HeaterSafety Information Theory of Operation Product IdentificationUnpacking Propane SupplyTo Start Heater InstallationOperation To Stop Heater StorageFlame Patterns To Restart HeaterSpecifications MaintenanceReplacement Parts Parts Under WarrantyTroubleshooting AccessoriesIllustrated Parts Breakdown RCCP80VParts List KEY Part Description QTY104781-01D Owners Registration Form Postage Required PROPANE/LP Forced AIR Heaters PROPANE/LP Convection Heaters GAS ChimeneasWarranty and Repair Service Table DES Matières Informations Concernant LA Sécurité AvertissementsIdentification DU Produit DéballagePrincipe DE Fonctionnement Alimentation EN PropaneMise EN Marche Détendeur avec aérateur dirigé vers le basAspect DE LA Flamme Aspect correct de la flammeCaractéristiques RemisageEntretien Arrêt DE L’APPAREILAccessoires DépannageDécomposition Illustrées DES Pièces Pièces Sous Garantie Liste DES PiècesPièces Détachées Pièces NON Couvertes PAR LA Garantie104781-01D Formulaire Dinscription DU Propriétaire Ruban Autres Produits DE Chauffage Pour L’EXTÉRIEUR Garantie ET Service APRÈS-VENTE

RCCP80V specifications

The Desa RCCP80V is a cutting-edge portable propane heater designed to deliver efficient and reliable heating in various applications. Renowned for its robust construction and advanced technology, the RCCP80V is ideal for outdoor gatherings, construction sites, garages, and emergency heat during power outages.

One of the main features of the Desa RCCP80V is its impressive heating capacity. With an output of 80,000 BTUs, this heater is capable of warming up to 2,000 square feet, making it suitable for both residential and commercial spaces. The adjustable heat settings allow users to customize the temperature according to their needs, ensuring maximum comfort.

The RCCP80V incorporates a variety of advanced technologies that enhance its performance and safety. It features an integrated safety shut-off system that automatically turns off the heater in the event of accidental tip-over, providing peace of mind during operation. Additionally, the heater is equipped with an oxygen depletion sensor that detects low oxygen levels in the air and triggers an automatic shut-off, ensuring safe usage in enclosed spaces.

Portability is another significant advantage of the Desa RCCP80V. The unit is designed with a compact and lightweight framework, making it easy to transport to different locations. Its durable construction means it can withstand harsh conditions and frequent mobility without compromising performance.

The heater also comes with a variable heat control knob that allows for precise temperature regulation. This feature enables users to maintain the desired warmth without wasting fuel, enhancing both efficiency and cost-effectiveness. The RCCP80V is compatible with standard 20-pound propane tanks, providing convenience and accessibility for refueling.

In terms of design, the Desa RCCP80V features a modern aesthetic, combining functionality with a sleek appearance that fits seamlessly into various environments. Its easy-to-use ignition system ensures quick and hassle-free startup, making it an excellent choice for those seeking immediate warmth.

Overall, the Desa RCCP80V stands out in the portable heater market due to its impressive heating capacity, safety features, portability, and efficient fuel usage. Whether for outdoor events, job sites, or emergency situations, the RCCP80V is a reliable choice for anyone in need of effective heating solutions.