Desa VP5D Operating Heater, Checking GAS Connections, For Your Safety Read Before Lighting

Page 10

® VP5D AND VP10A

PROPANE/LP GAS HEATERS

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater. See guidelines under Con- necting to Gas Supply, page 9.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1. Disconnect appliance with its appliance

main gas valve (control valve) and equip-

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to equipment shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Fig- ure 14).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 10 and 11). Check all other in- ternal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 11).

8.Replace front panel.

Open

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

 

ment shutoff valve from gas supply pip-

 

ing system. Pressures in excess of 1/2 psig

 

will damage heater regulator.

2.

Cap off open end of gas pipe where

 

equipment shutoff valve was connected.

3.

Pressurize supply piping system by ei-

 

ther using compressed air or opening

 

propane/LP supply tank valve.

4.

Check all joints of gas supply piping

 

system. Apply mixture of liquid soap

 

and water to gas joints. Bubbles form-

 

ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect heater and equipment

 

shutoff valve to gas supply. Check re-

 

connected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 14).

Equipment

C. Use only your hand to push in or turn

Shutoff

the gas control knob. Never use tools.

Valve

If the knob will not push in or turn

 

 

by hand, don’t try to repair it, call a

Closed

qualified service technician or gas

supplier. Force or attempted repair

 

Figure 14 - Equipment Shutoff Valve

may result in a fire or explosion.

Control Valve Location

D. Do not use this appliance if any part

has been under water. Immediately

Propane/LP

call a qualified service technician to

inspect the appliance and to replace

Supply Tank

any part of the control system and

 

 

any gas control which has been un-

 

der water.

Equipment

Shutoff

 

Valve

 

Figure 15 - Checking Gas Joints

 

10

104273

Image 10
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information PROPANE/LP GAS HeatersLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Heater to Wall InstallationInstallation Items Locating HeaterPlacing Heater On Mounting Screws Installing Two Mounting ScrewsInstalling Bottom Mounting Screw Removing Front Panel Of HeaterConnecting to GAS Supply External Regulator With VentPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Select Heating Level Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyVice person Gas leak. See Warning statement at Illustrated Parts Breakdown Parts ListVP5D ODS/PILOT VP10A ODS/PILOT Service Hints SpecificationsReplacement Parts Service Publications Technical104273 Warranty Information