Desa VP5D installation manual Inspecting Burner, Cleaning and Maintenance

Page 12

® VP5D AND VP10A

PROPANE/LP GAS HEATERS

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 19 shows a correct pilot flame pat- tern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appliance, page 11)

seeTroubleshooting, pages 13 through 15

Pilot Burner

Thermocouple

Figure 19 - Correct Pilot Flame Pattern

Figure 21 - Correct Burner Flame Pattern (Model VP10A Shown)

Figure 22 - Incorrect Burner Flame Pattern (Model VP10A Shown)

CLEANING AND MAINTENANCE

CLEANING BURNER PILOT AIR INLET HOLE

We recommend that you clean the unit every 2,500hoursofoperationoreverythreemonths.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot for dust and dirt.

3.Blow air through the ports/slots and holes in the burner.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 23). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed

Thermocouple

Pilot Burner

WARNING: Turn off heater and let cool before cleaning.

air is not available.

Pilot Air Inlet Hole

BAD PILOT/LP

GRH/OV 008

Figure 20 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 21 shows a correct burner flame pattern. Figure 22 shows an incorrect burner flame pattern.

If burner flame pattern is incorrect, as shown in Figure 22

turn heater off (see To Turn Off Gas to Appliance, page 11)

seeTroubleshooting, pages 13 through 15

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

ODS/PILOT AND BURNER ORIFICE

Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

Pilot Assembly

Figure 23 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

12

104273

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information PROPANE/LP GAS HeatersProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation ItemsInstalling Heater to Wall Locating HeaterInstalling Two Mounting Screws Installing Bottom Mounting ScrewPlacing Heater On Mounting Screws Removing Front Panel Of HeaterConnecting to GAS Supply External Regulator With VentFor Your Safety Read Before Lighting Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Operating HeaterManual Lighting Procedure Lighting InstructionsTo Select Heating Level To Turn OFF GAS To ApplianceCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyVice person Gas leak. See Warning statement at Parts List Illustrated Parts BreakdownVP5D ODS/PILOT VP10A ODS/PILOT Specifications Replacement PartsService Hints Service Publications Technical104273 Warranty Information