OWNER’S MANUAL
INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
CAUTION:Neverconnectheater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.
CAUTION: Use only new, black iron or steel pipe. Inter-
Installation must include a equipment shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be up- stream from heater (see Figure 13). An appliance main gas valve (equipment shutoff valve) shall be provided in an accessible location for turning on or shutting off the gas to the appliance.
IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.
Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
IMPORTANT: Hold pressure regulator with wrench when connecting it to gas pip- ing and/or fittings.
The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure
12.Pointing the vent down protects it from freezing rain or sleet.
Propane/LP | External |
Supply Tank | Regulator |
Vent
Pointing
Down
Figure 12 - External Regulator With Vent
3/8" NPT Pipe Nipple
Equipment
Shutoff
Valve *
From External Regulator (11" W.C. to 14" W.C. Pressure)
3" Minimum
Figure 13 - Gas Connection
Pressure
Regulator
Heater
Cabinet
Ground Joint
Union
Tee Joint |
|
|
|
|
Reducer |
| Test | ||
Bushing to |
| |||
| Gauge | |||
1/8" NPT |
| |||
| Connection * | |||
1/8" NPT |
| |||
|
| |||
Plug Tap |
|
|
| |
|
|
|
Tee |
|
|
|
Joint |
| Sediment | |
Pipe |
| ||
| Trap | ||
Nipple |
| ||
|
| ||
Cap |
|
|
|
Pointing Down
*A CSA/AGA
Continued
104273 | 9 |