Desa VP1600TB, VP2600TB installation manual Inspecting Burner, Cleaning and Maintenance

Page 13

OWNER’S MANUAL

OPERATING

HEATER

Continued

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions on page 12.

2.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instruc- tions, page 12.

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appliance, page 12)

seeTroubleshooting, pages 14 through 16

Pilot Burner

Thermocouple

GOOD PILOT/LP

GRH/OV 007

Figure 19 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

BAD PILOT/LP

GRH/OV 008

Figure 20 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 21 shows a correct burner flame pattern. Figure 22 shows an incorrect burner flame pattern.

If burner flame pattern is incorrect, as shown in Figure 22

turn heater off (see To Turn Off Gas to Appliance, page 12)

seeTroubleshooting, pages 14 through 16

Figure 21 - Correct Burner Flame Pattern

Bad Burner Pattern-Plaque GRH/OV 019

Figure 22 - Incorrect Burner Flame Pattern

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

ODS/PILOT AND BURNER ORIFICE

Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CLEANING BURNER PILOT AIR INLET HOLE

We recommend that you clean the unit every 2,500hoursofoperationoreverythreemonths.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot for dust and dirt.

3.Blow air through the ports/slots and holes in the burner.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 23). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

Pilot Air Inlet

Hole

Pilot Assembly

Figure 23 - Pilot Inlet Air Hole

104821

13

Image 13
Contents What to do if YOU Smell GAS Infrared VENT-FREE PROPANE/LP GAS HeaterInfrared PROPANE/LP GAS Heater Safety InformationSafety Device Product FeaturesProduct Identification Local Codes UnpackingProviding Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Items InstallationLocating Heater Check GAS TypeMounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Typical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Turn OFF GAS To Appliance Lighting InstructionsThermostat Control Operation Shutting Off HeaterInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Gas leak. See Warning statement at Replacement Parts SpecificationsService Publications Technical Service HintsIllustrated Parts Breakdown KEY Part Number Description QTY Parts ListVP2600TB Parts List Equipment Shutoff Valve GA5010 AccessoriesFloor Mounting Stand Models VP1600TB GA4000B Models VP2600TB GA4010B104821 Warranty Information

VP1600TB, VP2600TB specifications

The Desa VP2600TB and VP1600TB are advanced ventilation and heating products designed to enhance indoor air quality and provide comfort through efficient temperature management. These models are particularly suitable for residential and commercial spaces that require reliable heating solutions without compromising on energy efficiency.

One of the standout features of both the VP2600TB and VP1600TB is their innovative heating technology. These units utilize a high-efficiency heating element that significantly reduces energy consumption while delivering consistent warmth. The VP2600TB is designed for larger spaces, offering a powerful output for effective heating, while the VP1600TB caters to smaller areas, making it an ideal choice for localized heating needs.

The thermostatic control feature allows users to set and maintain their desired temperature easily. With an integrated digital thermostat, both models ensure that users can monitor and adjust heating levels with precision, minimizing waste and optimizing comfort. This feature is particularly appealing in fluctuating weather conditions where a reliable temperature regulation system is essential.

In terms of design, both models feature a sleek and modern aesthetic that can seamlessly blend into various interior decors. The compact design of the VP1600TB makes it perfect for smaller rooms, while the robust structure of the VP2600TB ensures durability and longevity for heavy-duty use.

Another key characteristic of the Desa VP series is their safety features. Both models come equipped with a safety shut-off mechanism that activates in the event of overheating, providing peace of mind for users. Moreover, the burnished steel construction and cool-touch housing are engineered to reduce the risk of accidental burns and enhance the overall safety profile.

The VP2600TB and VP1600TB also incorporate advanced filtration systems that help improve indoor air quality. These units utilize high-capacity filters to capture dust, allergens, and other airborne particles, ensuring that the air circulated within the space is clean and healthy.

In summary, the Desa VP2600TB and VP1600TB offer a comprehensive solution for heating and ventilation needs, combining efficiency, safety, and advanced technology in one package. Their ability to adapt to various environments while maintaining energy efficiency makes them an excellent investment for anyone looking to enhance comfort within their space.